Texas Instruments THS10082 Manuals

ManualLib has 2 documents for the Texas Instruments THS10082: 1 user manual, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 1Datasheet 1

Key facts

Model
THS10082
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-06-11

Start here

Texas Instruments THS1206/THS12082/THS10064/THS10082 Evaluation Module User's Guide

Texas Instruments THS1206/THS12082/THS10064/THS10082 Evaluation Module User's Guide

User Manual 28 pages · 662 KB · EN

This user's guide serves as a reference book for the THS1206/THS12082/THS10064/THS10082 evaluation module (EVM). It describes the operation and usage of these 12-bit and 10-bit analog-to-digital converter (ADC) evaluation modules. The document covers EVM description, common-connector interface details, physical descriptions including bill of materials, and schematics.

Read online

Texas Instruments THS10082 specifications

Resolution10 Bits
Differential Nonlinearity Error+1 LSB
Integral Nonlinearity Error+1 LSB

Source: Texas Instruments THS10082 Analog-to-Digital Converter Datasheet

All Texas Instruments THS10082 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What are the operating temperature ranges for the THS10082?

The THS10082C is characterized for operation from 0°C to 70°C, and the THS10082I is characterized for operation from -40°C to 85°C.

From: Texas Instruments THS10082 Analog-to-Digital Converter Datasheet

Does the device support single-ended or differential inputs?

Yes, it supports simultaneous sampling of two single-ended signals or one differential signal.

From: Texas Instruments THS10082 Analog-to-Digital Converter Datasheet

What is the required supply voltage range for the evaluation module?

The evaluation module requires a supply voltage ranging from 6 V to 10 V.

From: Texas Instruments THS1206/THS12082/THS10064/THS10082 Evaluation Module User's Guide

What is the analog input voltage range for single-ended operation?

The analog input voltage range is from -1 V to 1 V.

From: Texas Instruments THS1206/THS12082/THS10064/THS10082 Evaluation Module User's Guide