Texas Instruments THS1007 Manuals

ManualLib has 2 documents for the Texas Instruments THS1007: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
THS1007
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-06-11

Start here

Texas Instruments THS1007 10-Bit 6-MSPS ADC Datasheet

Texas Instruments THS1007 10-Bit 6-MSPS ADC Datasheet

Datasheet 36 pages · 303 KB · EN

The THS1007 is a CMOS, low-power, 10-bit, 6 MSPS analog-to-digital converter (ADC) designed for applications in radar, imaging, high-speed acquisition, and communications. It features simultaneous sampling of four analog inputs, which can be configured individually as single-ended or differential inputs. The device includes internal control registers to program the ADC into the desired mode and provides internal voltage references for 1.5 V and 3.5 V.

The THS1007 operates with a single 5-V supply and offers a signal-to-noise and distortion ratio of 59 dB at 2 MHz. It supports a parallel microcontroller/DSP interface and a glueless DSP interface. The device is available in a TSSOP package with two variants: the THS1007C for 0°C to 70°C operation and the THS1007I for -40°C to 85°C operation.

Read online

Texas Instruments THS1007 specifications

Resolution10 Bits
Sampling Rate6 MSPS
Signal-to-Noise and Distortion Ratio59 dB
Integral Nonlinearity Error+1 LSB
Differential Nonlinearity Error+1 LSB
Power Dissipation216 mW Max

Source: Texas Instruments THS1007 10-Bit 6-MSPS ADC Datasheet

All Texas Instruments THS1007 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the maximum sampling rate of the THS1007?

The maximum sampling rate is 6 MSPS.

From: Texas Instruments THS1007 10-Bit 6-MSPS ADC Datasheet

How many analog inputs does the THS1007 support?

The device supports simultaneous sampling of 4 analog inputs.

From: Texas Instruments THS1007 10-Bit 6-MSPS ADC Datasheet

Can the THS1007 sample single-ended or differential signals?

Yes, it supports simultaneous sampling of 4 Single-Ended Signals or 2 Differential Signals or a combination of both.

From: Texas Instruments THS1007 Datasheet

What is the maximum power dissipation of the THS1007?

The device dissipates a maximum of 216 mW when operating with AVpp = DVpp = 5 V and BVpp = 3.3 V.

From: Texas Instruments THS1007 Datasheet