Key facts
- Brand
- Texas Instruments
- Model
- THS10064
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2012-06-11
Start here

Texas Instruments THS1206/THS12082/THS10064/THS10082 Evaluation Module User's Guide
This user's guide serves as a reference book for the THS1206/THS12082/THS10064/THS10082 evaluation module (EVM). It describes the operation and usage of these 12-bit and 10-bit analog-to-digital converter (ADC) evaluation modules. The document covers EVM description, common-connector interface details, physical descriptions including bill of materials, and schematics.
Read onlineTexas Instruments THS10064 specifications
| Resolution | 10 Bits |
|---|---|
| Conversion Speed | 6 MSPS |
| Integral Nonlinearity (INL) | +/- 1 LSB |
| Differential Nonlinearity (DNL) | +/- 1 LSB |
| Max Power Dissipation | 216 mW |
| Analog Supply Voltage (AVDD) | 5 V |
All Texas Instruments THS10064 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the required supply voltage range for the evaluation module?
The evaluation module requires a supply voltage ranging from 6 V to 10 V.
From: Texas Instruments THS1206/THS12082/THS10064/THS10082 Evaluation Module User's Guide
What is the analog input voltage range for single-ended operation?
The analog input voltage range is from -1 V to 1 V.
From: Texas Instruments THS1206/THS12082/THS10064/THS10082 Evaluation Module User's Guide
What is the operating temperature range for the THS10064C?
The THS10064C is characterized for operation from 0°C to 70°C.
What is the operating temperature range for the THS10064I?
The THS10064I is characterized for operation from -40°C to 85°C.