Maxim MAX492/MAX494/MAX495 Single/Dual/Quad Op Amps Datasheet
This document describes the dual MAX492, quad MAX494, and single MAX495 operational amplifiers. These devices combine excellent DC accuracy with rail-to-rail input and output operation, allowing them to function from a single supply of +2.7V to +6V or split supplies up to +/-3V.
Read onlineMaxim MAX492 specifications
| Supply Voltage Range | +2.7V to +6V (Single) or +/-1.35V to +/-3V (Split) |
|---|---|
| Supply Current | < 150uA per Op Amp |
| Gain-Bandwidth Product | 500kHz |
| Input Noise Voltage Density | 25nV/sqrt(Hz) |
| Output Short-Circuit Current | 30 mA |
Source: Maxim MAX492/MAX494/MAX495 Single/Dual/Quad Op Amps Datasheet
All Maxim MAX492 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the maximum supply current for each op amp?
Each amplifier requires less than 150uA of supply current.
From: Maxim MAX492/MAX494/MAX495 Single/Dual/Quad Op Amps Datasheet
Can these operational amplifiers drive a 1kQ load?
Yes, the devices are capable of driving a 1kQ load even with low supply current.
From: Maxim MAX492/MAX494/MAX495 Single/Dual/Quad Op Amps Datasheet
What supply voltage range do the MAX492/494/495 support?
They operate from a single 2.7 V to 6 V supply or from dual ±1.35 V to ±3 V supplies.
How much quiescent current does each op amp draw?
Each amplifier consumes less than 150 µA of supply current.
What supply voltage range do the MAX492/494/495 op‑amps support?
They operate from 2.7 V up to 6 V.
What is the maximum quiescent current per op‑amp?
The maximum quiescent current is 150 µA per amplifier.