Maxim MAX213 Manuals

ManualLib has 4 documents for the Maxim MAX213: 2 user manuals, 2 datasheets. Every file can be read online or downloaded as a PDF for free.

User Manual 2Datasheet 2

Key facts

Brand
Maxim
Model
MAX213
Industry
Industrial
Documents
4
Languages
EN
Last added
2012-05-09

Start here

Maxim MAX200/MAX211/MAX213 RS-232 Transceiver Datasheet

Maxim MAX200/MAX211/MAX213 RS-232 Transceiver Datasheet

Datasheet 20 pages · 542 KB · EN

The MAX200‑MAX211/MAX213 family are 5 V RS‑232 and V.28 transceivers that generate the required ±10 V RS‑232 levels using on‑board charge‑pump converters. They meet EIA/TIA‑232E and CCITT V.28 specifications at data rates up to 120 kbps and include shutdown modes for low‑power operation.

The devices are offered in 28‑pin SO and SSOP packages, support a wide operating temperature range, and provide features such as auto‑shutdown, receiver enable control, and low‑leakage shutdown currents (<1 pA). Ordering information, package dimensions, and detailed electrical characteristics are provided throughout the sheet.

Read online

Maxim MAX213 specifications

Maximum Data Rate120 kbits/sec
Supply Voltage+5 V (charge‑pump to +10 V)
Shutdown Current1 pA
Operating Temperature Range-40 °C to +85 °C (some parts to +125 °C)

Source: Maxim MAX200-MAX211/MAX213 RS-232 Transceiver Datasheet

All Maxim MAX213 documents by type

Questions answered in these manuals

Which packages are the MAX211 and MAX213 available in?

Both parts are offered in 28‑pin wide SO and 28‑pin shrink SSOP packages.

From: Maxim MAX200/MAX211/MAX213 RS-232 Transceiver Datasheet

What type of capacitor is recommended for the charge‑pump circuit?

Ceramic capacitors are suggested for the charge‑pump capacitors.

From: Maxim MAX200/MAX211/MAX213 RS-232 Transceiver Datasheet

What is the maximum data rate of the MAX200‑MAX213 transceivers?

The devices support up to 120 kbits per second.

From: Maxim MAX200-MAX211/MAX213 RS-232 Transceiver Datasheet

How much current does the shutdown mode consume?

In low‑power shutdown the current is typically 1 pA.

From: Maxim MAX200-MAX211/MAX213 RS-232 Transceiver Datasheet

What is the maximum data rate of the MAX200‑MAX211/MAX213 transceivers?

The devices support data rates up to 120 kbps.

From: Maxim MAX200-MAX211/MAX213 Datasheet

What is the shutdown supply current for the MAX213?

The MAX213 has a low‑power shutdown current of 1 pA.

From: Maxim MAX200-MAX211/MAX213 Datasheet