Maxim MAX291 Manuals

ManualLib has 3 documents for the Maxim MAX291: 2 user manuals, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 2Datasheet 1

Key facts

Brand
Maxim
Model
MAX291
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-05-09

Start here

DatasheetMAXIM MAX291 Data Sheet

Maxim MAX291 specifications

Filter order8th‑order
Corner‑frequency range (MAX291/292)0.1 Hz to 25 kHz
Clock‑to‑corner‑frequency ratio100:1 (MAX291/292), 50:1 (MAX295/296)
Package types8‑Pin DIP, 8‑Pin SO, 16‑Pin Wide SO
Maximum clock frequency2.5 MHz

Source: Maxim MAX291/MAX292/MAX295/MAX296 Lowpass Filter Datasheet

All Maxim MAX291 documents by type

Questions answered in these manuals

What is the maximum recommended clock frequency for these filters?

The maximum recommended clock frequency is 2.5 MHz.

From: Maxim MAX291/MAX292/MAX295/MAX296 8th‑Order Lowpass Switched‑Capacitor Filters Datasheet

Can the filters operate from a single power supply?

Yes, they can operate from a single +5 V supply.

From: Maxim MAX291/MAX292/MAX295/MAX296 8th‑Order Lowpass Switched‑Capacitor Filters Datasheet

What is the maximum clock frequency for the MAX291/292/295/296 filters?

The maximum recommended clock frequency is 2.5 MHz, which yields the highest corner frequencies of 25 kHz for MAX291/292 and 50 kHz for MAX295/296.

From: Maxim MAX291/MAX292/MAX295/MAX296 Lowpass Filter Datasheet

Can the filters be powered from a single supply?

Yes, they can operate from a single +5 V supply or from dual ±5 V supplies.

From: Maxim MAX291/MAX292/MAX295/MAX296 Lowpass Filter Datasheet