MAXIM MAX1265/MAX1267 handbook
The MAX1265/MAX1267 are low-power, 12-bit analog-to-digital converters (ADCs) featuring a successive-approximation ADC, automatic power-down, fast wake-up (2µs), an on-chip clock, +2.5V internal reference, and a high-speed 12-bit parallel interface. They operate with a single +2.7V to +3.6V analog supply. Power consumption is only 5.4mW at the maximum sampling rate of 265ksps. Two software-selectable power-down modes enable the MAX1265/MAX1267 to be shut down between conversions; accessing the parallel interface returns them to normal operation. Powering down between conversions can reduce supply current below 10µA at lower sampling rates. Both devices offer software-configurable analog inputs for unipolar/bipolar and single-ended/pseudo-differential operation. In single-ended mode, the MAX1265 has six input channels and the MAX1267 has two (three input channels and one input channel, respectively, when in pseudo-differential mode). Excellent dynamic performance and low power, combined with ease of use and small package size, make these converters ideal for battery-powered and data-acquisition applications or for other circuits with demanding power-consumption and space requirements.
Read onlineMaxim MAX126 specifications
| Resolution | 14 Bits |
|---|---|
| Throughput (1 channel) | 250 ksps |
| Input Voltage Range (MAX125) | +5 V |
| Power Dissipation | 250 mW |
Source: Maxim MAX125/MAX126 14‑Bit Simultaneous‑Sampling ADC Datasheet
All Maxim MAX126 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the input voltage range for the MAX125?
The MAX125 accepts an input voltage range of up to +5 V.
From: Maxim MAX125/MAX126 14‑Bit Simultaneous‑Sampling ADC Datasheet
What is the maximum sampling rate per channel for these converters?
The devices can achieve up to 250 ksps per channel.
From: Maxim MAX125/MAX126 14‑Bit Simultaneous‑Sampling ADC Datasheet