STMicroelectronics LIS331DLM Manuals

ManualLib has 3 documents for the STMicroelectronics LIS331DLM: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
LIS331DLM
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-08-10

Start here

ST LIS331DLM MEMS digital output motion sensor ultra low-power high performance 3-axes nano accelerometer handbook

ST LIS331DLM MEMS digital output motion sensor ultra low-power high performance 3-axes nano accelerometer handbook

Datasheet 38 pages · 679 KB · EN

The LIS331DLM is an ultra low-power, high-performance three-axis linear accelerometer belonging to the 'nano' family. It features a digital 2C/SPI serial interface standard output and is available in a small thin plastic Land Grid Array (LGA) package. The device is designed for applications requiring motion activated functions, free-fall detection, and intelligent power saving for handheld devices.

Read online

STMicroelectronics LIS331DLM specifications

Supply voltage2.16 V to 3.6 V
IO voltage1.8 V
Power consumptiondown to 10 HA
Full-scale range+429/+49/48g
Resolution8 bit
Operating temperature-40 °C to +85 °C
PackageLGA 16

Source: ST LIS331DLM MEMS digital output motion sensor ultra low-power high performance 3-axes nano accelerometer handbook

All STMicroelectronics LIS331DLM documents by type

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What is the supply voltage range for the LIS331DLM?

The device supports a wide supply voltage range from 2.16 V to 3.6 V.

From: ST LIS331DLM MEMS digital output motion sensor ultra low-power high performance 3-axes nano accelerometer handbook

What is the minimum power consumption of the LIS331DLM?

The ultra low-power mode consumption can go down to 10 HA.

From: ST LIS331DLM MEMS digital output motion sensor ultra low-power high performance 3-axes nano accelerometer handbook

What is the default output data rate at power-on?

The default output data rate is 50 Hz.

From: STMicroelectronics LIS331DLM Application Note AN2989

How many samples are required to settle after changing full scale?

The output requires 3 to 8 samples to settle.

From: STMicroelectronics LIS331DLM Application Note AN2989