Agilent 7500i ICP-MS Application Note: Lead Isotope Ratios in Dan-shen

Quadrupole Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used to determine lead (Pb) isotope ratios in Dan-shen, a type of herb used in Traditional Chinese Medicines (TCM), and in water and soil samples all taken from the same geographical location.


Agilent 7500i ICP-MS Application Note: Lead Isotope Ratios in Dan-shen - cover page
Brand
Agilent
Category
Other
Document type
Other
Language
English
Pages
8
File format
PDF
File size
201 KB
Published
12 June, 2012
Updated
01 October, 2023
Model
7500i
MD5 checksum
B4F59DB1BF4A3D3FF510DA862C2DF373

About this manual

This document is an application note describing a scientific study that utilized Quadrupole Inductively Coupled Plasma Mass Spectrometry (ICP-MS) to analyze lead isotope ratios in Dan-shen, a traditional Chinese medicine herb. The study aimed to verify if isotopic measurements could serve as a reliable method for fingerprinting the geographical origin of the herb, which is critical for ensuring its medicinal effectiveness. The research compared results from Dan-shen samples, soil, and water collected from various locations in China.

What's inside

  • Abstract
  • Introduction
  • Instrumentation
  • Reagents
  • Sample preparation
  • Optimization of the ICP-MS operation parameters
  • Results
  • Short-term Stability
  • Long-term Stability
  • Results of Pb Isotope Ratio Measurements

Specifications

RF power1250 W
Carrier Gas flow rate0.4 L/min
Make-up Gas flow rate0.9 mL/min
Sample uptake rateabout 50 uL/min
Integration time for 204Pb20sec
Integration time for 206Pb10sec
Integration time for 207Pb10sec
Integration time for 208Pb5 sec

Frequently asked questions

What instrument was used for the lead isotope ratio measurements?

An Agilent 7500i ICP-MS fitted with a PFA micro flow nebulizer was used throughout the study.

What standard was used for mass bias correction?

SRM981 from the National Institute of Standards & Technology was used for mass bias correction.

Can lead isotope ratios distinguish Dan-shen samples from different origins?

Yes, the results show that it is possible to distinguish Dan-shen samples originating from different geographical areas using Pb isotope ratio measurements.