Key facts
- Brand
- Maxim
- Model
- MAX4502
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2012-06-05
Start here

Maxim Integrated MAX4501/MAX4502 Low-Voltage SPST CMOS Analog Switches Datasheet
The MAX4501/MAX4502 are single-pole/single-throw (SPST), low-voltage, single-supply, CMOS analog switches. The MAX4501 is normally open (NO) while the MAX4502 is normally closed (NC). These devices operate continuously with a single supply between +2V and +12V and can handle rail-to-rail analog signals.
Read onlineMaxim MAX4502 specifications
| Supply Voltage Range | +2V to +12V |
|---|---|
| On-Resistance (Typical) | 250 Ω at +5V |
| Off-Leakage Current (+25°C) | 1nA |
| Turn-On Time (Typical) | 75ns |
| Operating Temperature Range | -55°C to +125°C (MAX4501MJA) |
Source: Maxim Integrated MAX4501/MAX4502 Low-Voltage SPST CMOS Analog Switches Datasheet
All Maxim MAX4502 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the difference between MAX4501 and MAX4502?
The MAX4501 is normally open (NO) while the MAX4502 is normally closed (NC).
From: Maxim Integrated MAX4501/MAX4502 Low-Voltage SPST CMOS Analog Switches Datasheet
What logic levels are compatible with a +5V supply?
The digital input has 0.8V and 2.4V logic thresholds, ensuring TTL/CMOS-logic compatibility.
From: Maxim Integrated MAX4501/MAX4502 Low-Voltage SPST CMOS Analog Switches Datasheet
What is the maximum conversion rate of the MAX1172?
The maximum conversion rate is 30 MHz.
What are the power supply voltage requirements for the MAX1172?
The device requires +5.0V and -5.2V power-supply voltages.
What supply voltage range do the MAX4501/MAX4502 support?
They operate from a single supply of +2 V to +12 V.
From: Maxim MAX4501/MAX4502 Low-Voltage SPST CMOS Analog Switch Datasheet
What is the off‑leakage current at 25 °C?
The off‑leakage current is 1 nA at +25 °C.
From: Maxim MAX4501/MAX4502 Low-Voltage SPST CMOS Analog Switch Datasheet