Key facts
- Brand
- Texas Instruments
- Model
- SN54ALS653
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2012-06-06
Start here

TEXAS INSTRUMENTS SN54ALS652 SN54ALS653 SN54AS651 SN54AS652 SN74ALS651A SN74ALS652A SN74ALS653 SN74ALS654 SN74AS651 SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS handboo
The document describes a family of devices consisting of bus-transceiver circuits, D-type flip-flops, and control circuitry arranged for multiplexed transmission of data directly from the data bus or from internal storage registers. These components feature independent registers and enables for A and B buses, allowing for real-time and stored data transfer without typical decoding glitches.
Read onlineTexas Instruments SN54ALS653 specifications
| Supply Voltage (VCC) | 4.5 V to 5.5 V |
|---|---|
| High-Level Input Voltage (VIH) | 2 V |
| Low-Level Input Voltage (VIL) | 0.8 V |
| High-Level Output Current (IOH) | -15 mA |
| Clock Frequency (fCLOCK) | 0 to 40 MHz |
All Texas Instruments SN54ALS653 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
- TEXAS INSTRUMENTS SN54ALS652 SN54ALS653 SN54AS651 SN54AS652 SN74ALS651A SN74ALS652A SN74ALS653 SN74ALS654 SN74AS651 SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS handboo 22 p
- TEXAS INSTRUMENTS SN54ALS652 SN54ALS653 SN54AS651 SN54AS652 SN74ALS651A SN74ALS652A SN74ALS653 SN74ALS654 SN74AS651 SN74AS652 handbook 22 p
Questions answered in these manuals
What is the operating temperature range for SN54ALS devices?
The SN54ALS family operates over a military temperature range of -55°C to 125°C.
What is the operating temperature range for SN74ALS devices?
The SN74ALS family operates from 0°C to 70°C.
What is the maximum high‑level output current for the SN74ALS series?
The SN74ALS series can source up to –15 mA on a high‑level output.