Key facts
- Brand
- Analog Devices
- Model
- ADCMP343
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2022-11-29
Start here

ADCMP341/ADCMP343 Dual 0.275% Comparators and Reference with Programmable Hysteresis Data Sheet
The ADCMP341/ADCMP343 are dual low power, high accuracy comparators featuring a 400 mV reference and programmable hysteresis via a resistor string. They operate within a supply range of 1.7 V to 5.5 V with a typical quiescent current of 6.5 µA, making them ideal for portable applications and low voltage system monitoring. The devices include open-drain outputs that support wired-AND connections and are available in a small 8-lead SOT-23 package.
Read onlineAnalog Devices ADCMP343 specifications
| Threshold Voltage | 400.4 mV |
|---|---|
| Threshold Voltage Accuracy | ±0.275 % |
| Supply Range | 1.7 V to 5.5 V |
| Quiescent Current | 6.5 µA typical |
| Input Bias Current | ±5 nA maximum |
| Operating Temperature Range | -40°C to +125°C |
| Package Type | 8-Lead SOT-23 |
Source: ADCMP341/ADCMP343 Dual 0.275% Comparators and Reference with Programmable Hysteresis Data Sheet
All Analog Devices ADCMP343 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the threshold voltage of the ADCMP341/ADCMP343?
The threshold voltage is 400 mV with an accuracy of ±0.275%.
From: ADCMP341/ADCMP343 Dual 0.275% Comparators and Reference with Programmable Hysteresis Data Sheet
How is hysteresis programmed?
Hysteresis is determined using three resistors in a string configuration connected to the ±INA_U and ±INA_L pins.
From: ADCMP341/ADCMP343 Dual 0.275% Comparators and Reference with Programmable Hysteresis Data Sheet
What is the supply voltage range for the ADCMP341/ADCMP343?
The devices operate within a supply range of 1.7 V to 5.5 V.
What is the typical quiescent current?
The typical quiescent current is 6.5 µA.
What supply voltage range do the ADCMP341/ADCMP343 support?
They operate from 1.7 V up to 5.5 V.
How accurate is the threshold voltage?
The threshold voltage accuracy is ±0.275 % at 25 °C and 3.3 V supply.