Agilent 33500 series Manuals

ManualLib has 2 documents for the Agilent 33500 series: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Agilent
Model
33500 series
Industry
Electronics
Documents
2
Languages
ZH · EN
Last added
2026-09-29

Start here

Agilent 33500 Series Function/Arbitrary Waveform Generator User Guide

Agilent 33500 Series Function/Arbitrary Waveform Generator User Guide

User Manual 283 pages · 3.8 MB · ZH

This guide covers the Agilent 33500 series 30 MHz function and arbitrary waveform generator, describing its front‑panel controls, menu structure, and available waveforms. It includes quick‑start steps, detailed feature explanations, and programming information for remote interfaces.

Safety precautions, grounding requirements, and environmental limits are detailed, along with technical specifications such as frequency range, sample rate, resolution, and supported interfaces. The manual also provides troubleshooting tips and calibration procedures. This manual is written in Chinese.

Read online

Agilent 33500 series specifications

Maximum Frequency30 MHz
Sample Rate250 MSa/s
Resolution16 bits
Standard Waveforms16
Arbitrary Waveform Memory1 M points (optional 16 M points)
InterfacesGPIB, USB, LAN
SCPI CompatibilityYes
LXI Class C ComplianceYes

Source: Agilent 33500 Series Function/Arbitrary Waveform Generator User Guide

All Agilent 33500 series documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What safety precautions must be taken before powering on the instrument?

Connect the instrument to a protective earth ground, avoid explosive environments, and ensure all safety measures are observed before applying power.

From: Agilent 33500 Series Function/Arbitrary Waveform Generator User Guide

How can I change the duty cycle of a square wave?

Select the square‑wave function, press the Duty Cycle soft key, and adjust the value using the knob or numeric keypad as described in the quick‑start section.

From: Agilent 33500 Series Function/Arbitrary Waveform Generator User Guide

What safety steps must be taken before applying power?

Make all connections before applying power, select the appropriate line voltage on the fuse module, and ground the instrument via the earth terminal.

From: Agilent 33500 Series Function / Arbitrary Waveform Generator User’s Guide

What is the maximum waveform memory length?

The generator supports up to 1 MSa of arbitrary waveform memory, expandable to 16 MSa with Option 002.

From: Agilent 33500 Series Function / Arbitrary Waveform Generator User’s Guide