Agilent 710 Series Manuals

ManualLib has 6 documents for the Agilent 710 Series (Other): 6 product leaflets. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 6

Key facts

Brand
Agilent
Model
710 Series
Category
Other
Industry
Industrial
Documents
6
Languages
IT · FR · EN
Last added
2012-07-06

Start here

Agilent 710 Series ICP-OES Product Leaflet

Agilent 710 Series ICP-OES Product Leaflet

Product Leaflet 8 pages · 259 KB · IT

The Agilent 710 Series ICP-OES is designed for laboratories with medium-to-low workloads requiring uncompromised performance for routine inorganic analysis. It features a robust plasma and a single-view plasma design that offers an extended dynamic range with limited interference, ensuring highly reliable results even with complex matrices. The system is also suitable for educational institutions and industries needing compliance with WEEE/RoHS directives. This manual is written in Italian.

Read online

Agilent 710 Series specifications

Target Analytes22
Analysis Time (USEPA 1605.3)3 min and 34 sec
Detection Limitsug/L
Sample Matrix Handlingup to 5% dissolved salts

Source: Agilent 710 Series ICP-OES Product Leaflet

All Agilent 710 Series documents by type

Questions answered in these manuals

What is the analysis time for 22 target analytes?

The measurement of 22 target analytes requires only 3 minutes and 34 seconds per sample.

From: Agilent 710 Series ICP-OES Product Leaflet

What is the Agilent ICP-OES series 710 designed for?

It offers uncompromised performance for laboratories with medium-to-low workloads that perform routine ICP-OES analyses.

From: Agilent 710 Series ICP-OES Product Leaflet

How long does it take for the plasma to stabilize after being turned on?

The instrument allows you to analyze samples in less than 10 minutes after lighting the plasma.

From: Agilent 710 Series ICP-OES Product Brochure

What is the maximum percentage of dissolved salts the Agilent 710 can handle routinely?

The system can process up to 5% of dissolved salts in routine operation.

From: Agilent 710 Series ICP-OES Product Brochure

What is the difference between the 710 and 715 models?

The 710 is an axially viewed system ideal for high sensitivity, while the 715 is a radially viewed system ideal for difficult applications like oils and organic solvents.

From: Agilent 710 Series ICP-OES Specifications

What is the warm-up time from standby mode?

The warm-up time from standby mode is less than 10 minutes from plasma ignition.

From: Agilent 710 Series ICP-OES Specifications