Agilent 5975C Manuals

ManualLib has 20 documents for the Agilent 5975C: 10 product leaflets, 5 application notes, 2 datasheets, 3 user manuals. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 10Application Note 5Datasheet 2User Manual 3

Key facts

Brand
Agilent
Model
5975C
Documents
20
Languages
ES · JA · IT · DE · FR · EN · ZH
Last added
2012-07-09

Start here

Agilent 5975C Series MSD Guidance in Implementing High Ion Source Temperatures

Agilent 5975C Series MSD Guidance in Implementing High Ion Source Temperatures

User Manual 8 pages · 266 KB · EN

This technical overview discusses the implementation of high ion source temperatures for the Agilent 5975C Series Mass Selective Detectors (MSDs). While the default operating temperature is 230 °C, the 5975C ion source is fully configured for use up to 350 °C with the proper source configuration and ChemStation G1701EA software. The document outlines the advantages and disadvantages of higher temperatures, noting that while it can enhance signal for certain compounds like polynuclear aromatic hydrocarbons, it reduces source lifetime and requires strict leak prevention.

Read online

Agilent 5975C specifications

Mass Rangeup to 1050 amu
Ion Source Temperatureprogrammable up to 350°C
Quadrupole Materialproprietary gold-coated quartz

Source: Agilent 5975C Series GC/MSD Brochure

All Agilent 5975C documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the mass range of the Agilent 5975C?

The system offers a mass range up to 1050 amu.

From: Agilent 5975C Series GC/MSD Brochure

Can the ion source temperature be adjusted?

Yes, the inert solid ion source is programmable up to 350°C.

From: Agilent 5975C Series GC/MSD Brochure

How does Capillary Flow Technology improve column switching?

It allows for the exchange of columns between Gas Evolution Analysis (EGA) and Double Shot Analysis without venting the mass spectrometer.

From: Agilent Capillary Flow Technology Application for Pyrolysis GC/MS Analysis

What are the benefits of using backflushing?

Backflushing removes unnecessary high-boiling components, reducing analysis time by 21.3 minutes and preventing detector contamination.

From: Agilent Capillary Flow Technology Application for Pyrolysis GC/MS Analysis

What is the minimum detection limit for 2-MIB and geosmin using this system?

The system can detect both compounds at a concentration of 1 ppt.

From: Agilent 7890A/5975CTAD Stratum System Product Leaflet

How much time does one analysis cycle take with the optimized Stratum method?

The cycle time is reduced to 20 minutes, allowing for three samples per hour.

From: Agilent 7890A/5975CTAD Stratum System Product Leaflet