Agilent 1200 SL Manuals

ManualLib has 5 documents for the Agilent 1200 SL (Other device): 3 application notes, 2 user manuals. Every file can be read online or downloaded as a PDF for free.

Application Note 3User Manual 2

Key facts

Brand
Agilent
Model
1200 SL
Category
Other device
Industry
Industrial
Documents
5
Languages
JA · EN · IT
Last added
2012-07-06

Start here

Agilent 1200 SL User Manual

Agilent 1200 SL User Manual

User Manual 198 pages · 4.9 MB · EN

This manual from Agilent Technologies covers the 1200 SL system, offering guidance on safe handling, installation, and routine operation. It includes detailed sections on system overview, communication interfaces, and maintenance procedures.

Technical data such as maximum pressure, flow range, and supported communication ports are listed, along with troubleshooting tips and parts information to help users keep the instrument running efficiently.

Read online

Agilent 1200 SL specifications

Flow rate1 mL/min
Column temperature25 °C
Detection wavelength220 nm
Mobile phase A0.1% formic acid in water
Mobile phase B0.1% formic acid in acetonitrile
Minimum resolution achieved2.56

Source: Agilent 1200SL with RRHT Columns and ChromSword Application Note

All Agilent 1200 SL documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

How long does the automated method development run take?

The automated experiment analysis was executed over a period of 6 hours.

From: Agilent 1200SL System Analysis of Artemisinin Using RRHT Column and ChromSword Software Application Note

What is the minimum separation factor achieved in the final results?

The lowest value for the separation factor observed in the experiment was 256.

From: Agilent 1200SL System Analysis of Artemisinin Using RRHT Column and ChromSword Software Application Note

What software was used to aid in choosing the column?

ChromSword software was used to aid the analysts in choosing the column suited for the analysis.

From: Agilent 1200SL with RRHT Columns and ChromSword Application Note

How long did the automated method development take?

The fully automated, unattended method development was performed during a six-hour period.

From: Agilent 1200SL with RRHT Columns and ChromSword Application Note

What is the sample preparation method for milk?

An aliquot of 2 mL of milk is mixed with 4 mL of acetonitrile for protein precipitation, vortexed, and centrifuged for 10 minutes at 3500 rpm.

From: Agilent 1200SL LC/MS/MS Application Note for Trace Beta-Lactam Antibiotics in Milk

What is the maximum flow rate used in the LC conditions?

The flow rate is set to 0.3 mL/min.

From: Agilent 1200SL LC/MS/MS Application Note for Trace Beta-Lactam Antibiotics in Milk