The MAX3097E/MAX3098E are three-channel high-speed RS-485/RS-422 receivers with fault-detection circuitry and fault-status outputs. The receivers' inputs have fault thresholds that detect when the part is not in a valid state. The MAX3097E/MAX3098E indicate when a receiver input is in an open-circuit condition, short-circuit condition, or outside the common-mode range. They also generate a fault indication when the differential input voltage goes below a preset threshold. See Ordering Information or the Electrical Characteristics for threshold values. The fault circuitry includes a capacitor-programmable delay to ensure that there are no erroneous fault conditions even at slow edge rates. Each receiver is capable of accepting data at rates up to 32Mbps.

Read online

Maxim MAX309 specifications

ESD Protection (Air‑Gap)+15 kV
ESD Protection (Contact)+8 kV
ESD Protection (Human Body Model)+15 kV
Propagation‑Delay (MAX3093E)8 ns
Propagation‑Delay (MAX3094E)10 ns
Supply Voltage (MAX3093E)+5 V
Supply Voltage (MAX3094E)+3.3 V
Operating Temperature Range-40 °C to +85 °C
Operating Supply Current (no load, output enabled)2.4 mA
Maximum Receivers on Bus128

Source: Maxim MAX3093E / MAX3094E Quad RS-422/RS-485 Receiver Datasheet

All Maxim MAX309 documents by type

Questions answered in these manuals

What ESD protection levels does the MAX3093E/MAX3094E provide?

They are protected to +15 kV using the IEC 1000‑4‑2 Air‑Gap method, +8 kV using IEC 1000‑4‑2 Contact discharge, and +15 kV with the Human Body Model.

From: Maxim MAX3093E / MAX3094E Quad RS-422/RS-485 Receiver Datasheet

What supply voltages are required for the MAX3093E and MAX3094E?

The MAX3093E requires a +5 V supply, while the MAX3094E requires a +3.3 V supply.

From: Maxim MAX3093E / MAX3094E Quad RS-422/RS-485 Receiver Datasheet

What is the on‑resistance of the MAX308/MAX309?

The devices have an on‑resistance of less than 100 Ω.

From: Maxim MAX308/MAX309 Precision 8‑Channel/Dual 4‑Channel CMOS Analog Multiplexer Datasheet

What supply voltage ranges can the MAX308/MAX309 operate from?

They can operate from a single +5 V to +30 V supply or from bipolar ±5 V to ±20 V supplies.