Agilent Technologies 210-MS 220-MS 225-MS GC/MS Ion Trap Mass Spectrometer MS Workstation Version 6 Software Operation Manual
This document is the User's Guide and Reference Manual for the MS Workstation Version 6 software. It covers system configuration, instrument control, method creation and editing, data acquisition, calibration procedures, and report generation.
The manual details operations for controlling various mass spectrometers (210-MS, 220-MS, 225-MS) and gas chromatographs (431-GC, 450-GC). It includes instructions on using the MS/MS ion preparation methods, automated calibration blocks, and interactive graphics for data analysis.
Agilent MS Workstation Version 6 specifications
| Operating System | Windows 2000 or XP Professional |
|---|---|
| Processor Requirement | Pentium III (or higher), at least 1 GHz |
| Video Resolution | 1280 x 1024 x 256 resolution or greater |
| RAM Requirement | At least 1GB RAM |
Source: Agilent MS Workstation Version 6.9.2 Release/Update Notes
All Agilent MS Workstation Version 6 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Agilent MS Workstation Version 6.6 Release/Update Notes 31 p
- Agilent MS Workstation Version 6 Dioxin Reports User Guide 75 p
- Agilent MS Workstation Version 6.5 ToxProPlus Reporting Software User Manual 78 p
- Agilent MS Workstation v6 QuickEP Quick Start Guide 11 p
- Agilent 300 Series GC/MS LC/MS MS Workstation Version 6 Software Operation Manual 132 p
- Agilent Technologies 210-MS 220-MS 225-MS GC/MS Ion Trap Mass Spectrometer MS Workstation Version 6 Software Operation Manual 459 p
- Agilent Technologies 325-MS LC/MS MS Workstation Version 6 Software Operation Manual 112 p
Questions answered in these manuals
Which instruments are supported by MSWS 6.9.2?
The software supports GC/MS models including the 300-MS, 320-MS, 200-MS, 240-MS/4000, Saturn 2000, 1200, and 1200L, as well as LC/MS models like the 310-MS, 320-MS, 1200L, and 500-MS.
From: Agilent MS Workstation Version 6.9.2 Release/Update Notes
Does MSWS 6.9.2 support the 430-GC model?
No, MSWS 6.9.2 does not include drivers for the 430-GC, the 920-LC, or the 940-LC models.
From: Agilent MS Workstation Version 6.9.2 Release/Update Notes
What operating systems are supported?
Windows 2000 or XP Professional. Windows 98 is supported for Saturn 2000 users only, and Windows NT 4.0 (with service pack 6) is supported for Saturn 2000 or 1200 MS users only.
From: Agilent MS Workstation Version 6.5 Release/Update Notes
Can I install the NIST Library Option after installing the main software?
No, you should install the NIST Library Option before installing the MS Workstation to avoid having a demonstration version installed.
From: Agilent MS Workstation Version 6.5 Release/Update Notes
Which Windows power schemes should be configured to avoid communication failures?
Both System standby and System hibernates must be set to Never in the Power Options.
From: Agilent MS Workstation Version 6.6 Release/Update Notes
What Microsoft Access version is required for Custom Report templates?
Custom Report templates require Retail Access 2000 updated to Service Release 1 (SR-1) or later with Service Pack 5 for Jet 4.
From: Agilent MS Workstation Version 6.6 Release/Update Notes