Agilent 700 Series ICP Optical Emission Spectrometers User's Guide
The document serves as a comprehensive manual for the Agilent 700 Series ICP Optical Emission Spectrometers. It details critical safety practices regarding plasma hazards, compressed gases, and electrical risks before providing instructions on site preparation and installation requirements.
Subsequent sections guide users through operating procedures such as turning on the instrument, calibrating the detector, aligning the torch, and developing analysis methods using ICP Expert II software. The manual also includes troubleshooting tips and maintenance schedules for routine care.
Agilent 700 Series specifications
| Product Type | ICP-MS |
|---|---|
| Series | 7700 |
| Key Feature | Octopol Reaction System (ORS) |
| Key Feature | High Matrix Introduction-Kit (HMI) |
| Key Feature | ShieldTorch-System (STS) |
All Agilent 700 Series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the primary function of the Octopol Reaction System?
It is designed for the removal of spectral interferences that could falsify results, particularly effective in the Helium mode.
What is the stated size advantage of the Agilent 7700 series compared to previous models?
The 7700 is described as the smallest ICP-MS instrument currently available.
What is the primary use of the Agilent 7700 Series ICP-MS?
It is used for elemental determinations across a wide range of analyses, including environmental, semiconductor, food safety, geological, chemical, petrochemical, nuclear, clinical, forensic, and research applications.
From: Agilent 7700 Series ICP-MS Collision/Reaction Cell Modes Technical Overview
What mass range of elements was measured in the matrix tests?
The investigation focused on all of the elements in the mass range from 45 to 80.
From: Agilent 7700 Series ICP-MS Collision/Reaction Cell Modes Technical Overview
Does the software support automated startup?
Yes, both versions provide full control of the 7700 Series ICP-MS, including automated Startup and optimization.
From: Agilent ICP-MS MassHunter WorkStation Software (G7201A) for the Agilent 7700 Series ICP-MS Manual
What hardware does this software control?
The software provides configuration and control for the Agilent 7700 Series ICP-MS instruments and their accessories.
From: Agilent ICP-MS MassHunter WorkStation Software (G7201A) for the Agilent 7700 Series ICP-MS Manual