Agilent 6100 Series Manuals

ManualLib has 17 documents for the Agilent 6100 Series: 5 user manuals, 6 product leaflets, 2 quick start guides, 1 service manual. Every file can be read online or downloaded as a PDF for free.

User Manual 5Product Leaflet 6Quick Start Guide 2Service Manual 1

Key facts

Brand
Agilent
Model
6100 Series
Industry
Industrial
Documents
17
Languages
EN · ES · DE · FR · JA
Last added
2023-10-30

Start here

Agilent 6100 Series Single Quad LC/MS Quick Start Guide

Agilent 6100 Series Single Quad LC/MS Quick Start Guide

Quick Start Guide 36 pages · 1.7 MB · JA

The document serves as a quick start guide for the Agilent 6100 Series Single Quadrupole LC/MS systems. It highlights new features in the CB.03.01 SR1 software release, including faster scan rates up to 10 spectra per second for models 6130 and 6140, reduced band broadening, and improved cycle times of under 10 seconds.

The guide details the system configuration diagram, explains the various ChemStation display views such as Method & Run Control, Data Analysis, and MSD Tune, and provides operational tips. It also includes a troubleshooting section and safety warnings for users. This manual is written in Japanese.

Read online

Agilent 6100 Series specifications

Scan speed (System 6150)10,000 u/sec
Injection cycle timeLess than 10 seconds
Polarity switching speed20 ms
Mass range (System 6130)3000 uma
Sensitivity (System 6130)1 pg
LC flow rate (System 6150)Up to 2 ml/min

Source: Agilent TechnologiesSpanish version - Agilent 6100 Series Quadrupole LC/MS - Faster answers through high quality mass spectral information -5989-7871ES guide

All Agilent 6100 Series documents by type

Quick Start Guide 2

The shortest path to a working setup, usually only a few pages.

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

What sample and column must be ordered to perform the exercises in this guide?

You must order the Agilent electrospray LC demonstration sample (part number 59987-20033) and the Agilent ZORBAX SB-C18 column (2.1 mm x 30 mm, 3.5 µm, part number 873700-902).

From: Agilent 6100 Series Quadrupole LC/MS System Getting Started Guide

How long should the pump be flushed to ensure three times the volume passes through the binary pump?

You should flush the pump for approximately 3 minutes to ensure three times the volume passes through the binary pump.

From: Agilent 6100 Series Quadrupole LC/MS System Getting Started Guide

What is the fastest scan speed available for the Agilent 6100 Series?

The fastest scan speed is 10,000 u/second, which is available on the system 6150.

From: Agilent TechnologiesSpanish version - Agilent 6100 Series Quadrupole LC/MS - Faster answers through high quality mass spectral information -5989-7871ES guide

What is the minimum time required between injections on the Agilent 6100 Series?

The cycle time between injections is less than 10 seconds.

From: Agilent TechnologiesSpanish version - Agilent 6100 Series Quadrupole LC/MS - Faster answers through high quality mass spectral information -5989-7871ES guide

What applications are the Agilent 6100 Series LC/MS systems suitable for?

These systems are suitable for applications ranging from identity confirmation for combinatorial libraries of drug candidates to quantification of insecticides and herbicides in water samples.

From: Agilent 6100 Series LC/MS Quadrupole Systems Product Leaflet

How many sets of acquisition conditions can be used in a single run on systems 6130, 6120, and 6140?

Up to four different sets of acquisition conditions can be used in a single run.

From: Agilent 6100 Series LC/MS Quadrupole Systems Product Leaflet