Texas Instruments UCC28220/UCC28221 Manuals

ManualLib has 2 documents for the Texas Instruments UCC28220/UCC28221 (Power Management): 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
UCC28220/UCC28221
Industry
Electronics
Documents
2
Languages
ZH · EN
Last added
2026-11-18

Start here

Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet

Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet

Datasheet 31 pages · 755 KB · ZH

The UCC28220 and UCC28221 are BiCMOS interleaved dual channel PWM controllers designed for high output current converters and high power offline applications. They feature peak current mode control to ensure current sharing between channels and a programmable maximum duty cycle clamp between 60% and 90% per channel. The UCC28220 operates from a 12V supply, while the UCC28221 has a wider UVLO hysteresis for systems requiring higher voltage thresholds. Both devices have an 8V turn-off threshold and include internal slope compensation and opto-coupler interface for enhanced performance and noise immunity. This manual is written in Chinese.

Read online

Texas Instruments UCC28220/UCC28221 specifications

Maximum Duty Cycle Clamp60% to 90% per channel
UVLO Turn-On Threshold10 V for UCC28220, 13 V for UCC28221
Turn-Off Threshold8 V
Operating Voltage Range8.4 V to 14.5 V
Output Frequency900 kHz to 1100 kHz

Source: Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet

All Texas Instruments UCC28220/UCC28221 documents by type

Questions answered in these manuals

What is the maximum duty cycle clamp for each channel?

A precise maximum duty cycle clamp can be set to any value between 60% and 90% duty cycle per channel.

From: Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet

What are the UVLO turn-on thresholds for UCC28220 and UCC28221?

UCC28220 has an UVLO turn-on threshold of 10 V for use in 12-V supplies while UCC28221 has a turn-on threshold of 13 V for systems needing wider UVLO hysteresis.

From: Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet

What is the UVLO start threshold for the UCC28220?

The UVLO start threshold for the UCC28220 is 10 V.

From: Texas Instruments UCC28220, UCC28221 Interleaved Dual PWM Controller Datasheet

What is the UVLO start threshold for the UCC28221?

The UVLO start threshold for the UCC28221 is 13 V.

From: Texas Instruments UCC28220, UCC28221 Interleaved Dual PWM Controller Datasheet