Key facts
- Brand
- Texas Instruments
- Model
- UCC28220/UCC28221
- Category
- Power Management
- Industry
- Electronics
- Documents
- 2
- Languages
- ZH · EN
- Last added
- 2026-11-18
Start here

Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet
The UCC28220 and UCC28221 are BiCMOS interleaved dual channel PWM controllers designed for high output current converters and high power offline applications. They feature peak current mode control to ensure current sharing between channels and a programmable maximum duty cycle clamp between 60% and 90% per channel. The UCC28220 operates from a 12V supply, while the UCC28221 has a wider UVLO hysteresis for systems requiring higher voltage thresholds. Both devices have an 8V turn-off threshold and include internal slope compensation and opto-coupler interface for enhanced performance and noise immunity. This manual is written in Chinese.
Read onlineTexas Instruments UCC28220/UCC28221 specifications
| Maximum Duty Cycle Clamp | 60% to 90% per channel |
|---|---|
| UVLO Turn-On Threshold | 10 V for UCC28220, 13 V for UCC28221 |
| Turn-Off Threshold | 8 V |
| Operating Voltage Range | 8.4 V to 14.5 V |
| Output Frequency | 900 kHz to 1100 kHz |
Source: Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet
All Texas Instruments UCC28220/UCC28221 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the maximum duty cycle clamp for each channel?
A precise maximum duty cycle clamp can be set to any value between 60% and 90% duty cycle per channel.
From: Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet
What are the UVLO turn-on thresholds for UCC28220 and UCC28221?
UCC28220 has an UVLO turn-on threshold of 10 V for use in 12-V supplies while UCC28221 has a turn-on threshold of 13 V for systems needing wider UVLO hysteresis.
From: Texas Instruments UCC28220/UCC28221 Dual Channel PWM Controller Datasheet
What is the UVLO start threshold for the UCC28220?
The UVLO start threshold for the UCC28220 is 10 V.
From: Texas Instruments UCC28220, UCC28221 Interleaved Dual PWM Controller Datasheet
What is the UVLO start threshold for the UCC28221?
The UVLO start threshold for the UCC28221 is 13 V.
From: Texas Instruments UCC28220, UCC28221 Interleaved Dual PWM Controller Datasheet