Key facts
- Brand
- Omron
- Model
- E5GN
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2012-05-08
Start here
User ManualOMRON E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual
Omron E5GN specifications
| Thermocouple input indication accuracy | +0.3% of PV |
|---|---|
| Platinum (Pt) input indication accuracy | +0.2% of PV |
| Analog input indication accuracy | +0.2% FS |
| Power supply voltage options | 100‑240 VAC or 24 VAC/VDC |
| Number of auxiliary outputs | 0, 1, or 2 |
| Number of event inputs | 0, 1, or 2 |
| Communication interfaces | RS‑232C, RS‑485 |
Source: Omron E5GN Basic-type Digital Temperature Controller Datasheet
All Omron E5GN documents by type
User Manual 2
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Datasheet 1
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the indication accuracy of the thermocouple input?
The thermocouple input has an indication accuracy of ±0.3 % of the process value.
From: Omron E5GN Basic-type Digital Temperature Controller Datasheet
Which communication protocols are supported by the E5GN controller?
The controller can be equipped with either RS‑232C or RS‑485 communication interfaces.
From: Omron E5GN Basic-type Digital Temperature Controller Datasheet