Key facts
- Brand
- Omron
- Model
- G5CA
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH
- Last added
- 2012-06-01
Start here

Omron G5CA Power Relay Service Manual
This service manual provides detailed information for the Omron G5CA series power relays, including electrical ratings, mechanical dimensions, and environmental limits. It also lists the various coil voltage options and contact configurations for different model variants.
Installation guidelines, mounting recommendations, and certification data (UL, CSA, EN) are included to help technicians correctly integrate the relay into heating, industrial, or appliance applications. This manual is written in Chinese.
Omron G5CA specifications
| Operating time | 10ms or less |
|---|---|
| Insulation resistance | 1,000MΩ or more |
| Withstand voltage (coil to contact) | AC 2,500V 50/60Hz 1min |
| Mechanical life | 20 million times or more |
All Omron G5CA documents by type
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
Which safety certifications does the G5CA relay have?
It is certified to UL (file No. E41515) and CSA (file No. LR31928) standards.
What is the maximum switching capacity for the G5CA-1A-E model on AC resistive loads?
The maximum switching capacity is AC 250V at 10A.
What is the operating temperature range for the G5CA relay?
The operating temperature range is -25 to +70 degrees Celsius.