Agilent 7000A Manuals

ManualLib has 6 documents for the Agilent 7000A: 1 product leaflet, 4 application notes, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 1Application Note 4User Manual 1

Key facts

Brand
Agilent
Model
7000A
Documents
6
Languages
JA · EN
Last added
2012-07-06

Start here

Agilent 7000A Triple Quad GC/MS Data Acquisition Familiarization Guide

Agilent 7000A Triple Quad GC/MS Data Acquisition Familiarization Guide

User Manual 44 pages · 1.4 MB · EN

This document serves as a familiarization guide for the Agilent MassHunter Workstation Software, specifically focusing on Data Acquisition for the Agilent 7000A Triple Quad GC/MS. It instructs users on how to prepare their system and samples before beginning data acquisition exercises.

The guide walks users through developing an acquisition method by setting inlet and injection parameters, entering GC acquisition conditions, creating methods for finding precursor and product ions, and establishing MRM (Multiple Reaction Monitoring) methods. It also covers the creation of quantitative analysis batches and methods to quantitate unknown samples.

Read online

Agilent 7000A specifications

Detection Limit1 ppb
MRM Capability500 MRM/sec
Dwell Time5 ms

Source: Agilent 7000A GC/MS/MS Pesticide Screening Application Note

All Agilent 7000A documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the Agilent 7000A system used for?

It analyzes nitro-polycyclic aromatic hydrocarbons in atmospheric particulate matter using MRM mode without extra cleanup.

From: Agilent 7000A Triple Quadrupole GC/MS System Application Note

What are the dimensions of the DB-5MSUI column used?

The column is 15 m long with an inner diameter of 0.25 mm and a film thickness of 0.25 um.

From: Agilent 7000A Triple Quadrupole GC/MS System Application Note

What instrument is used for pesticide screening in TCM?

The Agilent 7000A GC/MS/MS is used to screen pesticides in Traditional Chinese Medicine.

From: Agilent 7000A GC/MS/MS Pesticide Screening Application Note

What mode is used to reduce matrix interference?

Multiple Reaction Monitoring (MRM) mode is used to reduce matrix interference.

From: Agilent 7000A GC/MS/MS Pesticide Screening Application Note

What is the limit of detection for nitro-PAHs using this method?

The limit of detection for these solutes was around 1 to 5 pg.

From: Agilent 7000A Triple Quadrupole GC/MS System Application Note

Can crude air particulate extracts be analyzed directly?

Yes, direct analysis of the crude air particulate extract could be performed due to the enhanced selectivity of the MS/MS detection mode.

From: Agilent 7000A Triple Quadrupole GC/MS System Application Note