Texas Instruments UC1842/3/4/5 Current Mode PWM Controller Datasheet
The UC1842/3/4/5 family of control ICs provides necessary features to implement off-line or DC-to-DC fixed frequency current mode control schemes with a minimal external parts count. The device includes internally implemented circuits such as under-voltage lockout, a precision reference, logic for latched operation, and a PWM comparator that also provides current limit control.
Read onlineTexas Instruments UC1842 specifications
| Operating Supply Current | 1 to 17 mA |
|---|---|
| Maximum Duty Cycle (UC1842/3) | 95 to 100 % |
| Start-Up Current | < 1 mA |
Source: Texas Instruments UC1842/3/4/5 Current Mode PWM Controller Datasheet
All Texas Instruments UC1842 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What are the UVLO thresholds for the UC1842?
The UC1842 has a start threshold of 16V and an off threshold of 10V.
From: Texas Instruments UC1842/3/4/5 Current Mode PWM Controller Datasheet
What are the under-voltage lockout thresholds for the UC1842?
The UC1842 has a UVLO threshold of 16V to turn on and 10V to turn off.
From: Texas Instruments UC1842/3/4/5 Current Mode PWM Controller Datasheet
What is the start‑up current of the UC1842 series?
The start‑up current is less than 1 mA.
From: TEXAS INSTRUMENTS UC1842/3/4/5 UC2842/3/4/5 UC3842/3/4/5 CURRENT MODE PWM CONTROLLERhandbook
What are the UVLO thresholds for the UC1842 device?
UVLO turns on at 16 V and turns off at 10 V.