This document serves as an operation manual for the ABB ACS800 drive running Standard Application Software version 7.x. It details procedures for starting up the drive unit, controlling it via I/O ports or a control panel, and managing various operational modes such as ID Run and startup guidance.
The guide covers extensive topics including parameter configuration, functional programming (macros), actual signal monitoring, fault tracking, and fieldbus communication protocols like Modbus. It also explains how to use the control panel for local operation, viewing status lines, and clearing fault records. This manual is written in Chinese.
ABB ACS800 specifications
| Operation Mode | Vendor Specific (ABB drive protocol) |
|---|---|
| PPO type | PPO4 |
| PZD3 OUT | 3 |
| PZD3 IN | 6 |
Source: ABB ACS800 Series Inverter PROFIBUS-DP Control Method
All ABB ACS800 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- ABB ACS800 Diode Rectifier Control Program Firmware Manual 84 p
- ABB ACS800 Standard Application Software 7.x Operation Manual 244 p
- ABB ACS800 Pump Control Application Program 7.2 Firmware Manual 242 p
- ABB ACS800 CraneDrive Control Manual
- ABB acs800 FOCH0320-50 FOCH0260-70 FOCH0610-70 filter solutions manual 26 p
- ABB ACS800 Firmware Manual 214 p
How to use the product for one specific task, with worked examples.
Disassembly, diagnostics and part numbers, for repair.
- ABB ACS800-17 Hardware Manual 14 p
- ABB ACS800 Hardware Manual 134 p
- ABB ACS800-17 Hardware Manual 230 p
- ABB ACS800-37 Drive Hardware Manual 252 p
- ABB ACS800-07/U7 Hardware Manual 142 p
- ABB ACS800-31 Hardware Manual 126 p
- ABB ACS800-07 Drive Hardware Manual 138 p
- ABB ACS800-02/U2 Drive Hardware Manual 128 p
Instruction set, parameters and examples for configuring or programming the device.
Questions answered in these manuals
What voltage is required for the internal connections between the control boards?
The internal connections between the control boards require a 24 V DC power supply.
From: ABB ACS800 Diode Rectifier Control Program Firmware Manual
What is the software version covered in this manual?
This manual covers Standard Application Software version 7.x.
From: ABB ACS800 Standard Application Software 7.x Operation Manual
How can faults be cleared on the drive?
Faults can be viewed and cleared using the control panel or through specific fault reset procedures described in the manual.
From: ABB ACS800 Standard Application Software 7.x Operation Manual
How should the Operation Mode be set for an ABB ACS800 inverter on PROFIBUS‑DP?
Set the Operation Mode to Vendor Specific, which selects the ABB drive protocol.
Which PPO type is required for the ACS800 inverter when using PROFIBUS‑DP?
Configure the PPO type parameter to PPO4.
Who is the intended reader of this manual?
The reader is expected to know standard electrical wiring practices, electronic components, and electrical schematic symbols.