Parameter changes needed to use a Demag conical brake motor with an ABB ACS800 drive.
This one-page ABB application note explains the parameter changes required to use a Demag conical brake motor with an ACS800 drive. It specifies running a reduced ID run and setting Start Mode to constant DC Mag in parameters 21.01 and 21.02, and notes that a standard ID run can cause the brake to engage and not tune properly.
| Reduced ID run parameter | 99.10 |
|---|---|
| Start Mode setting | constant DC Mag in 21.01 and 21.02 |
Run a reduced ID run and set Start Mode to constant DC Mag in parameters 21.01 and 21.02.
A standard ID run adjusts flux during the ID, which could cause the brake to engage and not tune properly.
They are typically found on cranes.