ABB TZIDC-110 Manuals

ManualLib has 3 documents for the ABB TZIDC-110: 2 user manuals, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 2Datasheet 1

Key facts

Brand
ABB
Model
TZIDC-110
Documents
3
Languages
ZH · EN
Last added
2026-09-28

Start here

ABB TZID/TZIDC/TZIDC110/TZIDC120/TZIDC200 Smart Valve Positioner User Manual

ABB TZID/TZIDC/TZIDC110/TZIDC120/TZIDC200 Smart Valve Positioner User Manual

User Manual 36 pages · 2.2 MB · ZH

The ABB TZID, TZIDC, TZIDC110, TZIDC120 and TZIDC200 series are compact, modular smart valve positioners for process automation. They feature electronic parameter configuration, built‑in LCD panel, and support multiple communication protocols such as PROFIBUS PA, FOUNDATION Fieldbus and HART.

The document provides step‑by‑step installation guidance for linear and angular actuators, details electrical connections, wiring diagrams, and lists technical specifications including input signal range, output pressure, temperature limits, and safety certifications. It also explains configuration, diagnostics and maintenance procedures. This manual is written in Chinese.

Read online

ABB TZIDC-110 specifications

Input signal range4‑20 mA (0‑100 %)
Output pressure range0‑6 bar (0‑90 psi)
Operating temperature-40 °C to 85 °C
Enclosure protection ratingIP65 / NEMA 4X
Power supply voltage5‑11 V DC
Resolution> 16 000 steps

Source: ABB TZID/TZIDC/TZIDC110/TZIDC120/TZIDC200 Smart Valve Positioner User Manual

All ABB TZIDC-110 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the input signal range for the TZID series positioners?

The input signal range is 4 mA to 20 mA, representing 0 % to 100 % of the measured position.

From: ABB TZID/TZIDC/TZIDC110/TZIDC120/TZIDC200 Smart Valve Positioner User Manual

What are the operating temperature limits?

The positioners can operate from –40 °C up to +85 °C.

From: ABB TZID/TZIDC/TZIDC110/TZIDC120/TZIDC200 Smart Valve Positioner User Manual

What is the operating temperature range for the TZIDC-110 positioner?

The device operates within a temperature range of -40 to 85 degrees Celsius.

From: ABB TZIDC-110 Electro-Pneumatic Positioner Datasheet

What communication protocol does the TZIDC-110 use?

Communication with the positioner occurs via PROFIBUS PA.

From: ABB TZIDC-110 Electro-Pneumatic Positioner Datasheet

What is the input signal range for the TZIDC positioner?

The input signal range is 4 mA to 20 mA, representing 0 % to 100 % of the measured variable.

From: ABB automate intelligence valve Locator TZID TZIDC TZIDC110 TZIDC120 TZIDC200 series Manual

What is the operating temperature range of the TZID series?

The devices can operate from –40 °C to +85 °C.

From: ABB automate intelligence valve Locator TZID TZIDC TZIDC110 TZIDC120 TZIDC200 series Manual