ABB 37LC drives Manuals

ManualLib has 2 documents for the ABB 37LC drives (Industrial Robot): 1 user manual, 1 service manual. Every file can be read online or downloaded as a PDF for free.

User Manual 1Service Manual 1

Key facts

Brand
ABB
Model
37LC drives
Documents
2
Languages
EN
Last added
2023-10-19

Start here

ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual

ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual

User Manual 72 pages · 1.3 MB · EN

This manual provides instructions for installing, configuring, and operating the emergency stop function for ABB ACS880-07/07LC/17/17LC/37/37LC drives. It covers safety precautions, wiring, parameter settings, and validation procedures for stop categories 0 and 1, including time and ramp monitoring. The manual also includes technical data, compliance standards, and maintenance guidelines for safety circuits.

The document is intended for qualified electrical professionals and includes diagrams, safety warnings, and detailed operational steps for integrating emergency stop functionality into drive systems.

Read online

ABB 37LC drives specifications

Safety performance with safety pulse encodersSee FSE-31 pulse encoder interface module user’s manual (3AXD50000016597 [English])
Safety data calculation assumptions for main contactorSwitched at low load current (normal use, ~0%, AC-1), used for emergency stop once a month, used for ordinary on/off once a day
Safety data calculation assumptions for main breakerSwitched at low load current (normal use, ~0%, AC-1), used for emergency stop once a month, used for ordinary on/off once a week

Source: ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual

All ABB 37LC drives documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

What safety standards does this manual comply with?

The manual complies with EN ISO 12100:2010, EN ISO 13849-1:2015, EN ISO 13849-2:2012, EN ISO 13850:2015, EN 60204-1:2018, IEC 61326-3-1:2017, IEC 61508-1:2010, IEC 61508-2:2010, IEC 61511-1:2016, EN 61800-5-2:2007, IEC 61800-5-2:2016, EN 62061:2005 + AC:2010 + A1:2013 + A2:2015, and European Machinery Directive 2006/42/EC.

From: ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual

Who is this manual intended for?

Only qualified electrical professionals with sufficient knowledge about functional, machine, and process safety are permitted to install, start up, and maintain the safety circuit.

From: ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual