ABB ACS850-04 Manuals

ManualLib has 6 documents for the ABB ACS850-04: 5 user manuals, 1 service manual. Every file can be read online or downloaded as a PDF for free.

User Manual 5Service Manual 1

Key facts

Brand
ABB
Model
ACS850-04
Industry
Industrial
Documents
6
Languages
EN · ZH
Last added
2012-08-07

Start here

Quick Start GuideABB ACS850-04 Quick Installation Guide

ABB ACS850-04 Quick Installation Guide

Quick Start Guide 8 pages · ZH

This guide provides step‑by‑step instructions for installing the ACS850‑04 (1.1 to 45 kW) drive module. It includes safety warnings, mechanical mounting procedures, power‑cable routing, and detailed wiring diagrams.

Key sections cover safety precautions, mechanical fixation to DIN rails, cable‑type requirements, torque values for terminal screws, control‑cable connections, and technical data such as protection class, ambient temperature limits, and current/voltage ratings. This manual is written in Chinese.

Read online

ABB ACS850-04 specifications

Protection classIP20
Maximum ambient temperature40 °C (104 °F)
Current rating≤ 100,000 A RMS
Maximum voltage500 V
Cable size (ACS850‑04‑03A0‑5…018A‑5)0.25 – 4 mm²

Source: ABB ACS850-04 Quick Installation Guide

All ABB ACS850-04 documents by type

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

What is the power range of the ACS850-04 module?

The ACS850-04 module is rated for 55 kW to 160 kW (75 hp to 200 hp).

From: ABB ACS850-04 frequency transformer module (55 160 kW 75 200 hp) solutions manual

When was this manual published?

The manual shows a copyright date of 2011.

From: ABB ACS850-04 frequency transformer module (55 160 kW 75 200 hp) solutions manual

What safety precautions are required before installing the ACS850‑04?

Only qualified electrical engineers may install or maintain the drive, ensure the drive is de‑energized, and lock the motor shaft mechanically before any connection.

From: ABB ACS850-04 Quick Installation Guide

What are the recommended tightening torques for the terminal screws?

For model ACS850‑04‑03A0‑5…018A‑5 the torque is 1.5 N·m (13 lbf·in); for ACS850‑04‑025A‑5…094A‑5 the torque is 3 N·m (25 lbf·in).

From: ABB ACS850-04 Quick Installation Guide

Can the ACS850-04 be repaired on‑site?

No, on‑site repair is not allowed; the unit must be returned to an authorized ABB service center.

From: ABB ACS850-04 Frequency Transformer Module Hardware Manual

What is the recommended wire size for the main power terminals?

The recommended maximum wire size for the main terminals is 10 mm² (AWG6).

From: ABB ACS850-04 Frequency Transformer Module Hardware Manual