ABB ACS880-01 Manuals

ManualLib has 6 documents for the ABB ACS880-01 (Industrial Robot): 3 user manuals, 1 product leaflet, 1 installation guide, 1 service manual. Every file can be read online or downloaded as a PDF for free.

User Manual 3Product Leaflet 1Installation Guide 1Service Manual 1

Key facts

Brand
ABB
Model
ACS880-01
Industry
Industrial
Documents
6
Languages
ZH · EN
Last added
2026-11-17

Start here

ABB ACS880-01 Industrial Drive Hardware Manual Chinese Edition

ABB ACS880-01 Industrial Drive Hardware Manual Chinese Edition

User Manual 204 pages · 17 MB · ZH

The document is a hardware manual for the ABB ACS880-01 Industrial Drive, designed for drives with power ratings ranging from 0.55 to 250 kW (0.75 to 350 hp). It serves as a comprehensive guide covering safety precautions, mechanical installation, electrical design and wiring, startup procedures, troubleshooting, and maintenance tasks such as replacing cooling fans and capacitors. This manual is written in Chinese.

Read online

ABB ACS880-01 specifications

Motor rated current12 A
Motor rated voltage230 V
Motor rated frequency50 Hz
Motor rated speed1360 rpm
Motor rated power0.18 kW
Motor rated power factor0.71
Supply voltage380...415 V
Demo box weightAbout 25 kg

Source: ABB ACS880-01 Drive Demo Box User Manual

All ABB ACS880-01 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

How much does the ACS880-01 demo box weigh?

About 25 kg.

From: ABB ACS880-01 Drive Demo Box User Manual

How long to wait after cutting input power before working on the drive?

Wait at least 5 minutes.

From: ABB ACS880-01 Drive Demo Box User Manual

What protection ratings are available for the ACS880-01?

IP21 is standard and IP55 is available as an option.

From: ABB ACS880-01 Wall-Mounted Single Drive Module Technical Sample

What safety function is included as standard?

Safety torque off (STO) is built in and is TÜV Nord certified.

From: ABB ACS880-01 Wall-Mounted Single Drive Module Technical Sample

Who is allowed to install and maintain the drive?

Only qualified electricians are permitted to perform installation and maintenance on the drive.

From: ABB ACS880-01 Drive Quick Installation Guide

How long must one wait after disconnecting power before working on the drive?

You must wait for 5 minutes to allow the intermediate circuit capacitors to discharge.

From: ABB ACS880-01 Drive Quick Installation Guide