Key facts
- Brand
- ABB
- Model
- ACS880-07
- Category
- Industrial Robot
- Documents
- 3
- Languages
- ZH · EN
- Last added
- 2026-10-23
Start here

ABB ACS880-07XT Drive Hardware Manual
This document is the Chinese hardware manual for the ABB ACS880-07XT industrial drive, covering power ratings from 400 to 1200 kW. It provides comprehensive instructions for installation, electrical connection, startup procedures, and maintenance tasks such as cleaning and module replacement. The manual also details technical data, including grid specifications, motor connection data, and efficiency ratings. This manual is written in Chinese.
Read onlineABB ACS880-07 specifications
| Power Rating | 400 to 1200 kW |
|---|---|
| Input Voltage (Voltage Level 3) | 380...415 V AC |
| Input Voltage (Voltage Level 5) | 380...500 V AC |
| Input Voltage (Voltage Level 7) | 525...690 V AC |
| Frequency | 48 to 63 Hz |
| Short-circuit Withstand Strength | 65 kA |
| Base Wave Power Factor | 0.98 |
| Efficiency | 96.0 ... 98.0% |
All ABB ACS880-07 documents by type
Disassembly, diagnostics and part numbers, for repair.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What tools are required for installation?
Required tools include cranes or forklifts, pry bars, jacks, rollers, screwdrivers, torque wrenches, and socket sets.
What is the maximum allowable floor deviation?
The maximum allowable deviation on a horizontal surface is 5mm within 3 meters.
What is the power range of the ACS880-07XT drive?
The drive is designed for a power range of 400 to 1200 kW.
What are the input voltage options for this drive?
The drive supports voltage levels 3 (380...415 V AC), 5 (380...500 V AC), and 7 (525...690 V AC).
What safety standards does this manual comply with?
The manual complies with EN ISO 12100:2010, EN ISO 13849-1:2015, EN ISO 13849-2:2012, EN ISO 13850:2015, EN 60204-1:2018, IEC 61326-3-1:2017, IEC 61508-1:2010, IEC 61508-2:2010, IEC 61511-1:2016, EN 61800-5-2:2007, IEC 61800-5-2:2016, EN 62061:2005 + AC:2010 + A1:2013 + A2:2015, and European Machinery Directive 2006/42/EC.
From: ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual
Who is this manual intended for?
Only qualified electrical professionals with sufficient knowledge about functional, machine, and process safety are permitted to install, start up, and maintain the safety circuit.
From: ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual