Key facts
- Brand
- ABB
- Model
- ACQ580-04
- Industry
- Electronics
- Documents
- 2
- Languages
- EN · ZH
- Last added
- 2026-11-22
Start here

ABB ACQ580-04 Drive Quick Installation Guide
This guide provides step-by-step instructions for installing the ABB ACQ580-04 drive module into a cabinet. It covers safety precautions, power cable selection, cooling requirements, and mounting procedures. The guide also includes diagrams and references to related manuals for more detailed information.
Safety is emphasized throughout, including warnings about handling the heavy drive module and ensuring proper grounding and insulation checks before connecting cables.
ABB ACQ580-04 specifications
| Drive Type | ACQ 580-505A-4 |
|---|---|
| Air Flow | 707 ft³/min |
| Heat Dissipation | 5602 W |
| Operating Temperature Range | -15 to +40 °C |
All ABB ACQ580-04 documents by type
The shortest path to a working setup, usually only a few pages.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
How do I check the insulation of the motor and motor cable?
Measure insulation resistance between each phase conductor and between each phase conductor and the Protective Earth conductor using a 1000 V DC measuring voltage. The insulation resistance of an ABB motor must exceed 100 Mohm.
What is the UL class fuse for the ACQ580-505A-4 drive?
The UL class fuse for the ACQ580-505A-4 drive is JJS-600.
What must be done if the drive has not been powered for a year or more?
The DC link capacitors must be reformed. Refer to the related manuals list or contact ABB technical support.
From: ABB ACQ580-04 Water Application Drive Quick Installation Guide
What motor cable does ABB recommend?
ABB recommends using symmetric shielded VFD motor cable.
From: ABB ACQ580-04 Water Application Drive Quick Installation Guide