ABB ACH580-01 Manuals

ManualLib has 2 documents for the ABB ACH580-01 (Industrial Robot): 1 installation guide, 1 service manual. Every file can be read online or downloaded as a PDF for free.

Installation Guide 1Service Manual 1

Key facts

Brand
ABB
Model
ACH580-01
Industry
Industrial
Documents
2
Languages
EN · ZH
Last added
2026-09-29

Start here

ABB ACS580-01/ACH580-01/ACQ580-01 Low Voltage Drives Main Switch and EMC C1 Filter Options Installation Supplement

ABB ACS580-01/ACH580-01/ACQ580-01 Low Voltage Drives Main Switch and EMC C1 Filter Options Installation Supplement

Installation Guide 264 pages · 28.3 MB · EN

The document is an installation supplement for ABB low voltage drives (ACS580‑01, ACH580‑01, ACQ580‑01) covering the main‑switch‑disconnector (+F278 or +F316) and the EMC C1 filter (+E223 or +F316). It references the R1…R5 quick installation and start‑up guides and applies to frame sizes R1 to R5.

It includes operation principles, safety instructions, wiring diagrams, technical data, compliance with EN 61800‑3:2004+A1:2012, and step‑by‑step installation procedures for the auxiliary connector and commissioning of the main switch.

Read online

ABB ACH580-01 specifications

Power Rating0.75 to 250 kW
Horsepower Rating1 to 350 hp
ApplicationHVAC
Release DateJanuary 17, 2017

Source: ABB Frequency Converter ACH580-01 Hardware Manual (0.75 to 250 kW, 1 to 350 hp)

All ABB ACH580-01 documents by type

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

How should the main switch be used safely?

Stop the drive, wait until the motor has stopped, turn the main switch to the OFF position, and attach a lock before working on the drive.

From: ABB ACS580-01/ACH580-01/ACQ580-01 Low Voltage Drives Main Switch and EMC C1 Filter Options Installation Supplement

Does the main switch isolate the input power cables?

No, the main switch does not isolate the input cables; they must be isolated at the distribution board or by opening the supply transformer disconnector before work.

From: ABB ACS580-01/ACH580-01/ACQ580-01 Low Voltage Drives Main Switch and EMC C1 Filter Options Installation Supplement

What is the power range of the ACH580-01 drive?

The drive covers a power range from 0.75 kW to 250 kW.

From: ABB Frequency Converter ACH580-01 Hardware Manual (0.75 to 250 kW, 1 to 350 hp)

Which application is this manual specifically for?

This manual is specifically for HVAC applications.

From: ABB Frequency Converter ACH580-01 Hardware Manual (0.75 to 250 kW, 1 to 350 hp)