User ManualABB ACS800-07/U7 Drive Hardware Manual

ABB ACS800-07/U7 Drive Hardware Manual

User Manual 142 pages · 7.1 MB · ZH

This hardware manual is for the ABB ACS800-07 and ACS800-U7 drives, covering units from 45 to 560 kW (50 to 600 HP). It includes safety instructions, mechanical and electrical installation, wiring, motor control and I/O board information, startup checks, and maintenance.

The manual also lists related firmware, application, and optional equipment manuals for the ACS800 drive family. This manual is written in Chinese.

Read online

All ABB ACS800-07 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

What power range does the ABB ACS800-07 cover?

It covers 500 to 2800 kW.

From: ABB ACS800-07 Inverter User Manual

What power range is stated for the ACS800-07?

The ACS800-07 is stated to have a power range of 500 to 2800 kW.

From: ABB ACS800-07 Inverter User Manual

What power range does the ACS800-07/U7 cover?

It covers 45 to 560 kW (50 to 600 HP).

From: ABB ACS800-07/U7 Drive Hardware Manual

How long should you wait after disconnecting input power before working on the drive?

Wait at least five minutes for the intermediate circuit capacitors to discharge.

From: ABB ACS800-07/U7 Drive Hardware Manual

What safety precautions are required before installing the ACS800‑07 drive?

Only qualified electrical engineers may install or maintain the drive, power must be disconnected, wait at least five minutes for capacitor discharge, and wear a grounding wrist strap.

From: ABB ACS800-07 Drive Hardware Manual

How is the braking resistor protected against overheating?

A main‑circuit contactor is strongly recommended and the resistor includes a thermal switch as standard to open the circuit if overheating occurs.

From: ABB ACS800-07 Drive Hardware Manual