Key facts
- Brand
- ABB
- Model
- 17LC
- Category
- Industrial Robot
- Documents
- 2
- Languages
- EN · ZH
- Last added
- 2023-10-19
Start here
ABB ACS800-17LC Water-Cooled Drive Hardware Manual
This hardware manual describes the ABB ACS800-17LC water-cooled drive for 55 to 5200 kW. It covers safety, hardware description, cabinet layouts, mechanical installation, electrical installation design, wiring, startup, fault tracing, maintenance, internal cooling circuits, and technical data.
The manual includes ratings for 400 V, 500 V, and 690 V supply types, frame sizes R7i and R8i, optional braking choppers and resistors, and connections to ACS800-1007LC or custom cooling units. This manual is written in Chinese.
ABB 17LC specifications
| Safety performance with safety pulse encoders | See FSE-31 pulse encoder interface module user’s manual (3AXD50000016597 [English]) |
|---|---|
| Safety data calculation assumptions for main contactor | Switched at low load current (normal use, ~0%, AC-1), used for emergency stop once a month, used for ordinary on/off once a day |
| Safety data calculation assumptions for main breaker | Switched at low load current (normal use, ~0%, AC-1), used for emergency stop once a month, used for ordinary on/off once a week |
Source: ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual
All ABB 17LC documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What safety standards does this manual comply with?
The manual complies with EN ISO 12100:2010, EN ISO 13849-1:2015, EN ISO 13849-2:2012, EN ISO 13850:2015, EN 60204-1:2018, IEC 61326-3-1:2017, IEC 61508-1:2010, IEC 61508-2:2010, IEC 61511-1:2016, EN 61800-5-2:2007, IEC 61800-5-2:2016, EN 62061:2005 + AC:2010 + A1:2013 + A2:2015, and European Machinery Directive 2006/42/EC.
From: ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual
Who is this manual intended for?
Only qualified electrical professionals with sufficient knowledge about functional, machine, and process safety are permitted to install, start up, and maintain the safety circuit.
From: ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual
What power range does the ACS800-17LC cover?
The ACS800-17LC water-cooled drive covers 55 to 5200 kW.
What does the hardware manual cover?
It covers safety, hardware description, mechanical and electrical installation, startup, fault tracing, maintenance, internal cooling, and technical data.