Mitsubishi M600 Mobile Phone User Manual

Mitsubishi M600 Mobile Phone User Manual

User Manual 52 pages · 2.5 MB · ZH

This manual explains how to use the Mitsubishi M600 mobile phone, covering basic operation, call functions, menu navigation, and safety precautions. It includes guidance on using the device without a SIM card, emergency calling, and compliance with wireless regulations.

The guide also lists the standard accessories supplied with the phone, such as battery, AC adapter, data cable, earphones, and Mini‑SD card, and offers maintenance tips to extend the device’s lifespan. This manual is written in Chinese.

Read online

Mitsubishi M600 specifications

Repetitive peak reverse voltage (VRRM)3300 V
Non‑repetitive peak reverse voltage (VDRM)3300 V
Reverse DC voltage (VRDC)2200 V
Continuous forward current (Ibc)600 A
Junction temperature range-40 °C to +150 °C
Storage temperature range-40 °C to +125 °C
Typical weight15 kg

Source: Mitsubishi Electric RM600DY-66S Fast Recovery Diode Module Datasheet

All Mitsubishi M600 documents by type

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the maximum reverse voltage rating of the RM600DY-66S?

The module is rated for a repetitive peak reverse voltage of 3300 V and a non‑repetitive peak reverse voltage of 3300 V.

From: Mitsubishi Electric RM600DY-66S Fast Recovery Diode Module Datasheet

What are the recommended mounting torque values for the module?

Main terminal screws (M6) should be tightened to 6.67–8.24 N·m, and the mounting screws (M6) to 2.84–3.43 N·m.

From: Mitsubishi Electric RM600DY-66S Fast Recovery Diode Module Datasheet

What are the allowed temperature limits for the device?

The junction temperature can operate from –40 °C up to +150 °C, and it can be stored from –40 °C to +125 °C.

From: Mitsubishi CM600DY-12NF IGBT Module Datasheet

What isolation voltage does the module provide between terminals and the base plate?

The isolation voltage is specified as 2500 Vrms for a 1‑minute test at 60 Hz.

From: Mitsubishi CM600HX-24A IGBT Module Datasheet

What are the allowable junction temperature limits?

The junction temperature can operate from –40 °C up to +150 °C.

From: Mitsubishi CM600HX-24A IGBT Module Datasheet

What is the typical weight of the CM600DU-24NF module?

The typical weight is 1200 g.

From: Mitsubishi CM600DU-24NF IGBT Module Datasheet