Mitsubishi QJ71CMO Manuals

ManualLib has 2 documents for the Mitsubishi QJ71CMO: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
QJ71CMO
Documents
2
Languages
ZH
Last added
2000-01-01

Start here

Mitsubishi Q Series MELSEC Communication Protocols Reference Manual

Mitsubishi Q Series MELSEC Communication Protocols Reference Manual

User Manual 473 pages · 8.5 MB · ZH

This Mitsubishi reference manual describes the MELSEC communication protocol used with MELSEC-Q Series programmable controllers, including the QJ71C24N, QJ71E71 and QJ71CMO serial and Ethernet modules. It covers frame types, data communication procedures, access to other stations, and communication timing.

The manual details commands for reading and writing device memory and buffer memory, PLC CPU status control, file control, user-registered frames, global functions, loopback tests, CPU monitoring, and remote password lock and unlock operations using QnA-compatible 3E/3C/4C, 2C, and A-compatible 1C/1E frames. This manual is written in Chinese.

Read online

Mitsubishi QJ71CMO specifications

Document typeMELSEC communication protocol reference manual
PLC seriesMELSEC-Q Series programmable controllers
Manual numberSH-080414C-A
Initial edition dateMarch 2003

Source: Mitsubishi Q Series MELSEC Communication Protocols Reference Manual

All Mitsubishi QJ71CMO documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

Which communication frames are covered in this manual?

The manual covers QnA-compatible 3E/3C/4C frames, QnA-compatible 2C frames, and A-compatible 1C and 1E frames.

From: Mitsubishi Q Series MELSEC Communication Protocols Reference Manual

What operations can be performed with the MELSEC protocol?

The manual describes device memory and buffer memory read/write, PLC CPU status control, file control, user-registered frames, global functions, loopback tests, CPU monitoring, and remote password lock and unlock.

From: Mitsubishi Q Series MELSEC Communication Protocols Reference Manual

What must be done before installing or removing the module?

All phases of the external power must be disconnected before installing or removing the module.

From: Mitsubishi QJ71C24 QJ71C24-R2 QJ71CMO Serial Communication Module User Reference Manual

How far apart should control or communication cables be spaced during installation?

Control or communication cables should be spaced at least 100 mm (3.9 inches) apart.

From: Mitsubishi QJ71C24 QJ71C24-R2 QJ71CMO Serial Communication Module User Reference Manual