Key facts
- Brand
- Mitsubishi
- Model
- QJ71E71
- Documents
- 3
- Languages
- ZH
- Last added
- 2026-11-04
Start here

Mitsubishi Q Series MELSEC Communication Protocols Reference Manual
This Mitsubishi reference manual describes the MELSEC communication protocol used with MELSEC-Q Series programmable controllers, including the QJ71C24N, QJ71E71 and QJ71CMO serial and Ethernet modules. It covers frame types, data communication procedures, access to other stations, and communication timing.
The manual details commands for reading and writing device memory and buffer memory, PLC CPU status control, file control, user-registered frames, global functions, loopback tests, CPU monitoring, and remote password lock and unlock operations using QnA-compatible 3E/3C/4C, 2C, and A-compatible 1C/1E frames. This manual is written in Chinese.
Mitsubishi QJ71E71 specifications
| Document type | MELSEC communication protocol reference manual |
|---|---|
| PLC series | MELSEC-Q Series programmable controllers |
| Manual number | SH-080414C-A |
| Initial edition date | March 2003 |
Source: Mitsubishi Q Series MELSEC Communication Protocols Reference Manual
All Mitsubishi QJ71E71 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the Ethernet module model?
QJ71E71-100.
From: Mitsubishi QJ71E71-100 Ethernet Module PanelMaster HMI Communication Setup
What driver is needed for the HMI?
C2BE11.dll / C2BE11.mod.
From: Mitsubishi QJ71E71-100 Ethernet Module PanelMaster HMI Communication Setup
Which communication frames are covered in this manual?
The manual covers QnA-compatible 3E/3C/4C frames, QnA-compatible 2C frames, and A-compatible 1C and 1E frames.
From: Mitsubishi Q Series MELSEC Communication Protocols Reference Manual
What operations can be performed with the MELSEC protocol?
The manual describes device memory and buffer memory read/write, PLC CPU status control, file control, user-registered frames, global functions, loopback tests, CPU monitoring, and remote password lock and unlock.
From: Mitsubishi Q Series MELSEC Communication Protocols Reference Manual
What safety precautions are required when using the Ethernet interface module?
Users must read the manual carefully, avoid writing to the system area, keep cables away from power lines, and follow the dangerous/careful warnings to prevent accidents.
From: Mitsubishi QJ71E71-100 / QJ71E71-B5 / QJ71E71-B2 Ethernet Interface Module User Manual
How should cables be installed around the Ethernet module?
Cables should be spaced at least 100 mm (3.94 in) apart to prevent noise and faults.
From: Mitsubishi QJ71E71-100 / QJ71E71-B5 / QJ71E71-B2 Ethernet Interface Module User Manual