Supply voltage (Veco)450 V
Collector‑emitter voltage (VCES)600 V
Continuous collector current15 A
Isolation voltage (pins to heat‑sink)1500 V

Source: Mitsubishi Semiconductor PS21964-4/4A/4C/4W Datasheet

All Mitsubishi PS4A documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

What is the maximum supply voltage for the PS21964 IPM?

The maximum supply voltage (Veco) is 450 V applied between the P‑N terminals.

From: Mitsubishi Semiconductor PS21964-4/4A/4C/4W Datasheet

What mounting torque is recommended for the heat‑sink screws?

A mounting torque of 0.69 Nm (typical) is recommended, with a range of 0.59 Nm to 0.78 Nm.

From: Mitsubishi Semiconductor PS21964-4/4A/4C/4W Datasheet

How should the VNC terminals be connected?

Either of the two VNC pins (9 or 16) should be connected to the 15 V power‑supply GND; the other pin can be left open.

From: MITSUBISHI SEMICONDUCTOR MITSUBISHI SEMICONDUCTOR PS21965-4/-4A/-4C/-4W Manual

What is the recommended isolation voltage between the module pins and the heat‑sink?

The isolation voltage is specified as 1500 V.