Mitsubishi RD09MUP2 Manuals

ManualLib has 2 documents for the Mitsubishi RD09MUP2 (Transistor): 1 datasheet, 1 application note. Every file can be read online or downloaded as a PDF for free.

Datasheet 1Application Note 1

Key facts

Model
RD09MUP2
Category
Transistor
Documents
2
Languages
EN
Last added
2012-03-21

Start here

MITSUBISHI RD09MUP2 Manual

MITSUBISHI RD09MUP2 Manual

Datasheet 9 pages · 338 KB · EN

The Mitsubishi RDOQSMUP2 is a silicon RF power MOSFET designed for UHF RF power amplifier applications. The sheet provides a description, key features such as >8 W output power and high efficiency, and typical application guidance for mobile‑radio output stages.

Detailed electrical characteristics, typical performance curves, test circuit diagrams, S‑parameter data, and extensive safety and handling precautions are included. RoHS compliance and warranty information are also provided.

Read online

Mitsubishi RD09MUP2 specifications

Drain‑to‑source voltage (VDS)40 V
Gate‑to‑source voltage range-5 V to +10 V
Maximum drain current (ID)4.0 A
Input power (Pin)1.6 W
Channel dissipation (Pch)0.83 W
Junction temperature (Tj)150 °C
Storage temperature range-40 °C to +125 °C
Thermal resistance (junction‑to‑case)1.5 °C/W
Operating frequency (example)520 MHz
Output power (example)8 W

Source: MITSUBISHI RD09MUP2 Manual

All Mitsubishi RD09MUP2 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What is the maximum drain‑to‑source voltage of the RDOQSMUP2?

The device is rated for a maximum drain‑to‑source voltage of 40 V.

From: MITSUBISHI RD09MUP2 Manual

Is the RDOQSMUP2 RoHS compliant?

Yes, the datasheet states that the RDOQSMUP2 is RoHS compliant.

From: MITSUBISHI RD09MUP2 Manual

What is the frequency range covered in this application note for the RD09MUP2?

The application note covers RF performance from 400 MHz to 527 MHz.

From: Mitsubishi Electric RDO9MUP2 Application Note AN-UHF-072-C

What drain voltage and quiescent current were used for the evaluation?

The evaluation used a drain voltage of 7.2 V and a quiescent drain current of 1 A.

From: Mitsubishi Electric RDO9MUP2 Application Note AN-UHF-072-C