Analog Devices ADM1185 Quad Voltage Monitor and Sequencer Datasheet
The ADM1185 integrates four precision comparators to monitor separate voltage rails and a digital core that provides sequencing and fault protection. It operates from a 2.7 V to 5.5 V supply, offers three open‑drain enable outputs (OUT1‑OUT3) and a common power‑good output (PWRGD), and is packaged in a 10‑lead MSOP.
Typical applications include power‑supply monitoring, power‑up sequencing for telecom and data‑communication equipment, and PCs/servers. The device features programmable voltage thresholds via external resistor dividers, internal timing delays for controlled start‑up, and robust protection against over‑voltage and undervoltage conditions.
Analog Devices ADM1185 specifications
| Operating Voltage Range (VCC) | 2.7 V to 5.5 V |
|---|---|
| Supply Current (I_VCC) typical | 80 µA |
| Input Rising Threshold (V_THR) typical | 0.6000 V |
| Output Low Voltage (V_OUTL) at VCC=2.7 V | 0.4 V |
| Leakage Current (I_ALERT) max | ±1 µA |
| VIN1 to OUT1 Rising Delay typical | 190 ms |
| Number of Open‑Drain Outputs | 4 (OUT1‑OUT3, PWRGD) |
Source: Analog Devices ADM1185 Quad Voltage Monitor and Sequencer Datasheet
All Analog Devices ADM1185 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What supply voltage range does the ADM1185 require?
The device operates from a VCC supply of 2.7 V to 5.5 V.
From: Analog Devices ADM1185 Quad Voltage Monitor and Sequencer Datasheet
How many open‑drain outputs are provided?
It provides four open‑drain outputs: OUT1, OUT2, OUT3, and PWRGD.
From: Analog Devices ADM1185 Quad Voltage Monitor and Sequencer Datasheet
What supply voltage range does the ADM1185 support?
The device operates from 2.7 V to 5.5 V on the VCC pin.
How many voltage inputs can be monitored by the ADM1185?
Four inputs (VIN1‑VIN4) can be programmed to monitor separate voltage rails.