Analog Devices ADM1186 Manuals

ManualLib has 2 documents for the Analog Devices ADM1186: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
ADM1186
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-05-04

Start here

Analog Devices ADM1186 Quad Voltage Sequencer and Monitor Handbook

Analog Devices ADM1186 Quad Voltage Sequencer and Monitor Handbook

Datasheet 28 pages · 284 KB · EN

The ADM1186‑1 and ADM1186‑2 are integrated four‑channel voltage monitoring and sequencing devices that operate from a 2.7 V to 5.5 V supply. They provide programmable up‑ and down‑sequencing, open‑drain enable outputs, a power‑good output, and a fault pin for safe power‑rail management.

The document includes functional descriptions, pin configurations, timing diagrams, absolute maximum ratings, and detailed electrical specifications for both the 20‑lead QSOP (ADM1186‑1) and 16‑lead QSOP (ADM1186‑2) packages.

Read online

Analog Devices ADM1186 specifications

Operating Voltage Range (VCC)2.7 V to 5.5 V
Undervoltage Lockout (UVLO) Threshold2.46 V
Input Threshold (VINx)0.600 V (typical)
Time‑Delay Accuracy5 % to 9 % (external capacitor 10 nF‑2.2 µF)
Output Low Voltage (SEQ_DONE, PWRGD, FAULT)0.4 V
Package Types20‑lead QSOP (ADM1186‑1) and 16‑lead QSOP (ADM1186‑2)

Source: Analog Devices ADM1186 Quad Voltage Sequencer and Monitor Handbook

All Analog Devices ADM1186 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What supply voltage range does the ADM1186 operate from?

The device operates from 2.7 V to 5.5 V on the VCC pin.

From: Analog Devices ADM1186 Quad Voltage Sequencer and Monitor Handbook

How many voltage channels can the ADM1186 monitor?

It monitors four separate voltage rails via VIN1 to VIN4 pins.

From: Analog Devices ADM1186 Quad Voltage Sequencer and Monitor Handbook

What does the SEQ_DONE pin indicate?

SEQ_DONE is an open‑drain pin that is asserted high to indicate that a power‑up sequence is complete.

From: Analog Devices ADM1186 Voltage Sequencer Datasheet

How many enable outputs are available on the ADM1186?

The device provides four open‑drain enable outputs, labeled OUT1 through OUT4.

From: Analog Devices ADM1186 Voltage Sequencer Datasheet