Toshiba TLP3043F Manuals

ManualLib has 2 documents for the Toshiba TLP3043F: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Toshiba
Model
TLP3043F
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-04-01

Start here

Toshiba TLP3041F(S)/TLP3042F(S)/TLP3043F(S) Photocoupler Datasheet

Toshiba TLP3041F(S)/TLP3042F(S)/TLP3043F(S) Photocoupler Datasheet

Datasheet 2 pages · 114 KB · EN

The TLP3041F(S), TLP3042F(S) and TLP3043F(S) are GaAs infrared emitting diode‑driven photo‑triac optocouplers packaged in a six‑lead DIP. They are intended for general electronics applications such as office machines, household equipment and industrial robotics.

The document lists key electrical parameters (peak off‑state voltage, trigger LED current, on‑state current, isolation voltage), mechanical ratings (creepage, clearance, insulation thickness) and safety approvals (UL1577, EN60065, EN60950, etc.). It also contains restrictions on use, warning that the devices must not be employed in safety‑critical or high‑risk equipment like medical, aerospace or traffic‑control systems.

Read online

Toshiba TLP3043F specifications

Peak Off‑State Voltage400 V (min)
Trigger LED Current (TLP3041F(S))15 mA (max)
On‑State Current100 mA (max)
Isolation Voltage5000 Vrms (min)
UL RecognitionUL1577
Maximum Operating Insulation Voltage1140 VPK
Creepage Distance8.0 mm (Min)
Clearance8.0 mm (Min)
Insulation Thickness0.5 mm (Min)

Source: Toshiba TLP3041F(S)/TLP3042F(S)/TLP3043F(S) Photocoupler Datasheet

All Toshiba TLP3043F documents by type

Questions answered in these manuals

What is the minimum peak off‑state voltage for the TLP3041F(S) series?

The minimum peak off‑state voltage is 400 V.

From: Toshiba TLP3041F(S)/TLP3042F(S)/TLP3043F(S) Photocoupler Datasheet

Which safety standards approve the TLP3041F(S) devices?

They are approved by UL1577, EN60065, EN60950 and other regional standards.

From: Toshiba TLP3041F(S)/TLP3042F(S)/TLP3043F(S) Photocoupler Datasheet

What is the peak off‑state voltage of the TLP3041F(S) series?

The peak off‑state voltage is 400 V minimum.

From: Toshiba TLP3041F(S) / TLP3042F(S) / TLP3043F(S) Photocoupler Datasheet

What trigger LED current is recommended for each model?

TLP3041F(S) requires up to 15 mA, TLP3042F(S) up to 10 mA, and TLP3043F(S) up to 5 mA (maximum values).

From: Toshiba TLP3041F(S) / TLP3042F(S) / TLP3043F(S) Photocoupler Datasheet