Toshiba TLP3051/TLP3052 Photocoupler Datasheet

Toshiba TLP3051/TLP3052 Photocoupler Datasheet

Datasheet 6 pages · 163 KB · EN

The TLP3051 and TLP3052 are photo‑triac optically coupled devices that combine a gallium arsenide infrared emitting diode with a triac in a six‑lead DIP package. They are intended for office machines, household equipment, and general electronics applications.

The document lists maximum ratings such as a 600 V off‑state voltage, 100 mA on‑state current, and 5000 Vrms isolation voltage, as well as recommended operating conditions, pin configuration, and safety restrictions for reliable system design.

Read online

Toshiba TLP3052 specifications

Peak off‑state voltage600 V (min.)
On‑state current100 mA (max.)
Isolation voltage5000 Vrms (min.)
Forward current (IF)50 mA
Supply voltage240 Vac
Storage temperature range-55 °C to 150 °C
Operating temperature range-40 °C to 100 °C
Weight0.44 g

Source: Toshiba TLP3051/TLP3052 Photocoupler Datasheet

All Toshiba TLP3052 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the maximum off‑state voltage for the TLP3051/TLP3052?

The device is rated for a peak off‑state voltage of at least 600 V.

From: Toshiba TLP3051/TLP3052 Photocoupler Datasheet

What supply voltage can be applied to the TLP3051/TLP3052?

The recommended supply voltage can be up to 240 Vac.

From: Toshiba TLP3051/TLP3052 Photocoupler Datasheet

What is the maximum off‑state voltage for the TLP3051/TLP3052?

The devices are rated for a peak off‑state voltage of at least 600 V.

From: Toshiba TLP3051/TLP3052 Photocoupler Datasheet

What isolation voltage must be observed when using these photocouplers?

A minimum isolation voltage of 5000 Vrms is required.

From: Toshiba TLP3051/TLP3052 Photocoupler Datasheet