Motorola MMSF7P03HD specifications
| Drain-to-Source Voltage (Vdss) | 30 Vdc |
|---|---|
| Continuous Drain Current (ID) | 7.0 Adc |
| Operating Temperature Range | -55 to 150 °C |
| Static Drain-to-Source On-Resistance (RDS(on)) | Max 35 mΩ @ Vgs=10V, Id=5.3A |
| Package Type | SO-8 Surface Mount |
All Motorola MMSF7P03HD documents by type
Datasheet 3
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the maximum drain current for this device?
The continuous drain current at 25°C is specified as 7.0 Amperes.
What are the operating temperature limits?
The device operates and stores within a range of -55 to 150 degrees Celsius.
What is the maximum drain‑to‑source voltage for the MMSF7P03HD?
The device is rated for a maximum drain‑to‑source voltage of 30 V.
What continuous drain current can the MMSF7P03HD handle?
It can conduct up to 7.0 A continuously at 25 °C.