Key facts
- Brand
- Mitsubishi
- Model
- FR-F500J
- Industry
- Industrial
- Documents
- 3
- Languages
- JA · ZH
- Last added
- 2012-03-13
Start here
Mitsubishi FR-F500J Frequency Converter User Manual (Basic Edition)
This is the basic edition user manual for the Mitsubishi FR-F500J series frequency converter. It describes installation, wiring, operation and control, parameter settings, alarms and protective functions, and specifications for models from FR-F540J-0.4K-CH to FR-F540J-15K-CH.
The manual also includes safety precautions, terminal wiring diagrams, parameter lists, troubleshooting guidance, maintenance notes, outline dimensions, and appendices for European and UL/cUL requirements. This manual is written in Chinese.
Mitsubishi FR-F500J specifications
| Frequency Range (standard) | 0.5‑120 Hz |
|---|---|
| Frequency Range (extended) | 0.5‑200 Hz |
| Rated Power (example model) | 0.4 kW |
| Rated Current (example model) | 5 A |
| Control Interface | RS‑485 |
| Motor Overload Protection | Electronic thermal relay |
Source: Mitsubishi Electric FR-F500J Frequency Converter User Manual
All Mitsubishi FR-F500J documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What safety precautions are required when installing the FR‑F500J?
Install the inverter on non‑flammable surfaces, keep the area clear of combustible materials, avoid touching live terminals, and ensure proper grounding before operation.
From: Mitsubishi Electric FR-F500J Frequency Converter User Manual
Does the FR‑F500J support RS‑485 communication?
Yes, the inverter includes an RS‑485 interface for communication with external devices.
From: Mitsubishi Electric FR-F500J Frequency Converter User Manual
Where must the inverter be installed?
It must be installed on a noncombustible object.
From: Mitsubishi FR-F500J Frequency Converter User Manual (Basic Edition)
What ambient temperature range is allowed?
The surrounding ambient temperature must be 10°C to 50°C without freezing.
From: Mitsubishi FR-F500J Frequency Converter User Manual (Basic Edition)
What is the operating ambient temperature range?
The ambient temperature should be 10°C to 50°C without freezing.
From: Mitsubishi Electric FR-F500J Frequency Converter User Manual (Basic)
What should be done before starting wiring or inspection?
Disconnect the power, wait 10 minutes, and check for residual voltage with a multimeter before proceeding.
From: Mitsubishi Electric FR-F500J Frequency Converter User Manual (Basic)