Analog Devices ADM6384 Manuals

ManualLib has 2 documents for the Analog Devices ADM6384: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
ADM6384
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-05-04

Start here

Analog Devices ADM6384 Datasheet

Analog Devices ADM6384 Datasheet

Datasheet 12 pages · 200 KB · EN

The ADM6384 supervisory circuit monitors power‑supply voltage in microprocessor‑based systems and generates a reset when the voltage falls below a programmable threshold. It is suited for microprocessor systems, computers, controllers, intelligent instruments, and portable equipment.

Key features include 31 selectable reset‑threshold options (1.58 V to 5.0 V), four reset‑timeout periods (1 ms, 20 ms, 140 ms, 1120 ms), a manual reset input, a push‑pull active‑low reset output, and operation over –40 °C to +125 °C in a 4‑lead SC70 package.

Read online

Analog Devices ADM6384 specifications

Operating Voltage Range1 V to 5.5 V
Supply Current (typical)7 pA
Reset Threshold Voltage (example)3.00 V to 3.15 V
Reset Timeout Period (minimum)1 ms
Operating Temperature Range–40 °C to +125 °C
Reset Output Current20 mA

Source: Analog Devices ADM6384 Datasheet

All Analog Devices ADM6384 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the operating voltage range of the ADM6384?

The device operates from 1 V up to 5.5 V.

From: Analog Devices ADM6384 Datasheet

How many reset timeout options does the ADM6384 provide?

It offers four timeout options: 1 ms, 20 ms, 140 ms, and 1120 ms.

From: Analog Devices ADM6384 Datasheet

What is the operating voltage range of the ADM6384?

The device operates from 1 V up to 5.5 V.

From: Analog Devices ADM6384 Datasheet

How many reset timeout options are available?

Four timeout options are provided: 1 ms, 20 ms, 140 ms, and 1120 ms.

From: Analog Devices ADM6384 Datasheet