Analog Devices ADN2815 Clock and Data Recovery IC Datasheet
The ADN2815 provides continuous‑rate clock and data recovery for serial data streams from 10 Mb/s up to 1.25 Gb/s. It automatically locks to any data rate without an external reference clock, includes a loss‑of‑lock indicator, and offers a PC interface for optional features. The device operates from a single 3.3 V supply and consumes about 390 mW typical power.
Typical applications include SONET OC‑1/‑3/‑12, Fibre Channel, Gigabit Ethernet, HDTV, WDM transponders, regenerators, test equipment, and broadband cross‑connects. The IC is supplied in a compact 5 mm × 5 mm 32‑lead LFCSP package.
Analog Devices ADN2815 specifications
| Data Rate | 10 Mb/s to 1.25 Gb/s |
|---|---|
| Power Supply Voltage | 3.0 V to 3.6 V |
| Power Supply Current (locked to 1.25 Gb/s) | 118 mA to 131 mA |
| Operating Temperature Range | -40 °C to +85 °C |
| Package | 5 mm × 5 mm 32‑lead LFCSP |
Source: Analog Devices ADN2815 Datasheet
All Analog Devices ADN2815 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
Does the ADN2815 require an external reference clock?
No, the device automatically locks to all data rates without the need for an external reference clock.
What are the power supply voltage requirements?
The device operates from a 3.0 V to 3.6 V supply.