Analog Devices TMP06 Manuals

ManualLib has 2 documents for the Analog Devices TMP06: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
TMP06
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-05-05

Start here

Analog Devices TMP05/TMP06 Datasheet

Analog Devices TMP05/TMP06 Datasheet

Datasheet 29 pages · 400 KB · EN

The TMP05 and TMP06 are low‑cost, 5‑lead temperature sensors that provide a modulated serial PWM output proportional to temperature. TMP05 offers a CMOS/TTL‑compatible push‑pull output, while TMP06 provides a flexible open‑drain output. Both devices operate over a wide temperature range (‑40 °C to +150 °C) and supply voltage range (3 V to 5.5 V), making them suitable for environmental control, computer thermal monitoring, and industrial process applications.

The datasheet details electrical specifications such as supply current (typical 370 µA at 3.3 V), accuracy (±0.5 °C typical at 25 °C), resolution (0.025 °C), and timing characteristics. It also includes absolute maximum ratings, ESD precautions, pin configurations, and application notes for daisy‑chain and one‑shot modes.

Read online

Analog Devices TMP06 specifications

Supply Voltage3 V to 5.5 V
Operating Temperature Range‑40 °C to +150 °C
Typical Supply Current @ 3.3 V370 µA
Temperature Accuracy @ 3.3 V (25 °C)±0.5 °C
Temperature Resolution0.025 °C
TMP05 Output TypePush‑pull CMOS/TTL compatible
TMP06 Output TypeOpen‑drain
Maximum Output Current10 mA

Source: Analog Devices TMP05/TMP06 Datasheet

All Analog Devices TMP06 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the operating temperature range of the TMP05/TMP06 sensors?

The sensors operate from –40 °C to +150 °C.

From: Analog Devices TMP05/TMP06 Datasheet

What supply voltage range do the TMP05/TMP06 require?

They require a supply voltage between 3 V and 5.5 V.

From: Analog Devices TMP05/TMP06 Datasheet

What supply voltage range do the TMP05/TMP06 sensors require?

They operate from 3 V to 5.5 V.

From: Analog Devices TMP05/TMP06 Temperature Sensor Handbook

What is the temperature measurement accuracy of the TMP05/TMP06 at 25 °C?

The typical accuracy is ±0.5 °C at 25 °C.

From: Analog Devices TMP05/TMP06 Temperature Sensor Handbook